跳至主要内容
临床试验/NCT04977115
NCT04977115Unknown不适用

Comparison of Intraocular Caliper-assisted and Verion Navigation System-assisted Capsulotomy in Phacoemulsification Surgery: A Randomized Non-inferiority Trial

Zhongshan Ophthalmic Center, Sun Yat-sen University1 个研究点 分布在 1 个国家目标入组 156 人开始时间: 2021年7月26日最近更新:
适应症

试验速览

阶段
不适用
入组人数
156
试验地点
1
主要终点
Deviation of horizontal and vertical diameter of capsulorhexis from the target diameter (5.3 mm)

研究概览

简要总结

The purpose of this study is to compare the accuracy of capsulotomy assisted by intraocular caliper and Verion navigation system in phacoemulsification surgery and postoperative visual quality of patients.

详细描述

Continuous curvilinear capsulorhexis (CCC) is an important and technically challenging procedure in cataract surgery. However, most surgeons perform CCC by experience or referring to the pupil size, which is highly subjective and the accuracy of capsulorhexis is unsatisfactory. The investigators developed a new modified intraocular caliper with standard calibration on the rinse needle, which can measure and locate the position of capsulorhexis. The surgeon can gently use the blunt needle in the front of the intraocular caliper to further make corresponding markers on the lens anterior capsule, and then carry out capsulotomy according to the marks. We found intraocular caliper-assisted capsulotomy can obviously improve the accuracy of capsulorhexis. The purpose of this study is to compare the accuracy and postoperative visual quality of intraocular caliper-assisted capsulotomy with those of digital image projection device VERION navigation system.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Other
盲法
Double (Participant, Outcomes Assessor)

入排标准

年龄范围
55 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Adults aged 55 to 80 years with age-related cataract;
  • Pupil diameter ≥ 6.5mm after pupil dilation;
  • Lens nuclear opacity grading score (LOCS III) lower than 4.0.

排除标准

  • Patients had previous intraocular surgery;
  • Patients with a diagnosed eye disease that may affect the functions of lens suspensory ligament such as previous ocular trauma, lens subluxation, pseudoexfoliation syndrome, retinal pigment degeneration;
  • Patients had other ocular diseases that impair visual function include optic neuropathy, uveitis, and tumor.
  • Refused to participate the study.

结局指标

主要结局

Deviation of horizontal and vertical diameter of capsulorhexis from the target diameter (5.3 mm)

时间窗: During the surgery

Images of the edges of IOL and capsulorhexis are taken at the end of the operation. Image J image analysis software is used to measure the horizontal diameter and vertical diameter of capsulorhexis with the diameter of IOL optical surface (6 mm) as the reference by two independently professional graders at the meantime, and further calculate the deviation of horizontal and vertical diameter of capsulorhexis from the target diameter (5.3 mm) .

次要结局

  • Intraocular aberrations(One month after surgery)
  • Grades of capsulorhexis-IOL overlap(During the surgery)
  • Intraocular lens tilt(One month after surgery)
  • Deviation of horizontal and vertical diameter of capsulorhexis from the target diameter (5.3 mm)(One month after surgery)
  • Intraocular lens decentration(One month after surgery)
  • Uncorrected and corrected visual acuity(One month after surgery)
  • Distance between pupil center and capsulorhexis center(During the surgery)
  • Ideal ratio of capsulorhexis(During the surgery)
  • Horizontal and vertical diameter of capsulorhexis(During the surgery)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验

Clinical Evaluation of Intraocular Caliper-assisted... | 临床试验