跳至主要内容
临床试验/NCT04359771
NCT04359771已完成4 期

Yellow Micropulse Laser 577-nm vs Infrared Diode Micropulse Laser 810-nm for the Treatment of Diabetic Macular Edema

Cairo University1 个研究点 分布在 1 个国家目标入组 15 人开始时间: 2018年1月22日最近更新:
适应症
干预措施

试验速览

阶段
4 期
状态
已完成
入组人数
15
试验地点
1
主要终点
Change in Central Retinal Thickness (CRT)

研究概览

简要总结

Anti-vascular endothelial growth factor (VEGF) therapy is currently the mainstay of treatment for diabetic macular edema (DME). One of the main obstacles of anti-VEGF therapy is the need of repeated injections, which carries both economic and compliance problems to the patients.there is a growing evidence that recognises the effectiveness of the use of micropulse laser (MPL) in treatment of DME. with MPL, it is possible to deliver a subthreshold laser that is above the threshold of biochemical effect but below the threshold of a visible, destructive lesion thereby preventing collateral damage.The MPL technique is available at near - infrared 810 nm diode laser (diode MPL) and at 577 nm (yellow MPL). The current study was conducted in order to compare the efficacy of both MPL techniques in the treatment of center involving DME.

详细描述

This was a prospective randomized comparative study that included 30 eyes of 15 patients with bilateral DME. The patients were recruited from the Retina Clinic at Kasr Al Ainy Hospital, Cairo University. The study's protocol was reviewed and approved by board of the ophthalmology department, Cairo University, and was in concordance with the tents of Declaration of Helsinki. Eligible patients were informed about the study's objectives, methodology, risks and benefits. A written informed consent was obtained from every patient included in this study.Preliminary examination was in the form of slit-lamp examination, fundus examination, intra ocular pressure measurement, and best corrected visual acuity (BCVA) measurement. A spectral domain optical coherence tomogram (OCT) scan was performed to all patients before treatment to measure the central retinal thickness (CRT). The eyes were randomized into two groups; one eye (right eye) of each patient was treated with 577-nm yellow MPL and the other eye (left eye) of the same patient with Infrared 810-nm diode MPL. Changes in the BCVA and CRT were measured after treatment at 1 and 3 months of follow up.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
20 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •bilateral diabetic macular edema
  • •center involving confirmed by Optical coherence tomogram (OCT)

排除标准

  • •any non-diabetic macular edema
  • •significant media opacities
  • •previous laser treatment, any intraocular surgery within the past 6 months
  • •previous intravitreal injections of any drug within the past 6 months

研究组 & 干预措施

Yellow MPL

Active Comparator

干预措施: Yellow micro-pulse laser (Device)

Diode MPL

Active Comparator

干预措施: Diode micro-pulse laser (Device)

结局指标

主要结局

Change in Central Retinal Thickness (CRT)

时间窗: baseline, at 1 month and 3 months after the intervention

detecting changes in the thickness of the center of the macula

Change in the Best Corrected Visual Acuity (BCVA)

时间窗: baseline, at 1 month and 3 months after the intervention

detecting changes in the the best corrected visual acuity in logMAR. A LogMAR chart comprises rows of letters and is used by ophthalmologists, optometrists and vision scientists to estimate visual acuity. This chart was developed at the National Vision Research Institute of Australia in 1976, and is designed to enable a more accurate estimate of acuity than do other charts (e.g., the Snellen chart). For this reason, the LogMAR chart is recommended, particularly in a research setting. A Snellen score of 6/6 (20/20), indicating that an observer can resolve details as small as 1 minute of visual angle, corresponds to a LogMAR of 0 (since the base-10 logarithm of 1 is 0); a Snellen score of 6/12 (20/40), indicating an observer can resolve details as small as 2 minutes of visual angle, corresponds to a LogMAR of 0.3 (since the base-10 logarithm of 2 is near-approximately 0.3), and so on.Therefore, a higher logMAR scores mean a worse outcome.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Ahmed Abdelbaki

lecturer of ophthalmology

Cairo University

研究点 (1)

Loading locations...

相似试验