跳至主要内容
临床试验/NCT04885725
NCT04885725已完成不适用

Association Between Knee Isokinetic Testing and Lower Limb Functional Performance and Limb Symmetry

University Hospital, Caen1 个研究点 分布在 1 个国家目标入组 20 人开始时间: 2019年12月5日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
20
试验地点
1
主要终点
Strength

研究概览

简要总结

This study aimed to evaluate the association between the isokinetic knee strength and/or proprioception performance with the functional performance on the functional Hop-tests and Y-balance test.

This study included 20 healthy individuals who performed an isokinetic assessment of knee proprioception (joint position sense, JPS and threshold to detection of passive motion, TDPM) and flexors/extensors strength. At the same time, they performed a functional testing consisting of three Hop-tests (single, triple and cross-over) and the Lower Quarter Y-Balance Test (YBT-LQ). We tested the correlation between the isokinetic and functional performances, and limb symmetry indexes.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Cross Sectional

入排标准

接受健康志愿者

入选标准

  • individuals under 45 years of age who performed at least 4 hours of physical activity per week.

排除标准

  • individuals unable to perform isokinetic muscle tests
  • individuals with a current or recent lower limb injury with time loss from sport participation within the previous month
  • individuals with previous severe knee injury (eg. Severe ligament tear, knee fracture)
  • individuals taking medications with potential balance/coordination side effects.

结局指标

主要结局

Strength

时间窗: one evaluation at a single point in time through study completion, an average of 4 months

Measurement of knee extensors and flexors peak strength (in newton.meter, Nm) on isokinetic dynamometer.

Knee proprioception, JPS1

时间窗: one evaluation at a single point in time through study completion, an average of 4 months

Measurement of knee proprioception by the passive repositioning technique (JPS, in degrees) on isokinetic dynamometer.

Knee proprioception, JPS2

时间窗: one evaluation at a single point in time through study completion, an average of 4 months

Measurement of knee proprioception by the active repositioning technique (JPS, in degrees) on isokinetic dynamometer.

Knee proprioception, TDPM

时间窗: one evaluation at a single point in time through study completion, an average of 4 months

Measurement of knee proprioception by the Threshold to Detection of Passive Motion (TDPM in degrees) on isokinetic dynamometer.

Functional testing, Hop tests

时间窗: one evaluation at a single point in time through study completion, an average of 4 months

Hop test. Single hop: Patients are instructed to stand on one leg and perform 1 jump as far as possible, landing on the same leg. The total distance is recorded (in cm) .Triple hop: Patients are instructed to stand on one leg and perform 3 hops as far as possible, landing on the same leg. The total distance for 3 consecutive hops is recorded (in cm). Cross-over hop test : The patient hops forward 3 times while alternately crossing over a marking The patient is instructed to position themselves such that the first of the 3 hops was lateral with respect to the direction of crossover The total distance hopped forward is recorded (in cm)

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Joffrey DRIGNY

Principal Investigator, Physician in the Sport Medicine Department (MD), PhD student

University Hospital, Caen

研究点 (1)

Loading locations...