Electromyographic Assessment of Onset and Recovery of Neuromuscular Blockade

NorthShore University HealthSystem1 个研究点 分布在 1 个国家目标入组 30 人开始时间: 2012年6月最近更新:
适应症

试验速览

阶段
不适用
状态
终止
入组人数
30
试验地点
1
主要终点
Train-of-four (TOF)ratio

研究概览

简要总结

Residual neuromuscular blockade (weakness) is a common occurrence in the postanesthesia care unit when muscle relaxant drugs have been used in the operating room. The only method of reliably detecting the presence of neuromuscular blockade is through the use of quantitative neuromuscular monitors. These devices measure and quantify the degree of muscle weakness and display the results on a screen. When using train-of-four (TOF) nerve stimulation, the ratio of the fourth muscle contraction (twitch) to the first twitch will be displayed; when this ratio is 90% (or 0.9) or greater, full recovery of muscle strength is present, and the endotracheal tube can be removed. At the present time, there is only one commercially-available quantitative monitor available in the United States -the TOF-Watch. It is not used by many clinicians because it requires experience to obtain accurate results, is expensive, and is subject to interference by factors in the operating room. The aim of this investigation is to examine a new quantitative monitor (the T4-EMG (EMG = electromyography) that may not be subject to the same limitations as the TOF-Watch AMG (AMG = acceleromyography). In order to study the accuracy of this new device, the T4-EMG will be compared to the current "clinical gold standard", the TOF-Watch.

详细描述

The aim of this investigation is to examine a new prototype of a quantitative monitoring instrument that will meet these requirements. Patients undergoing surgery under general anesthesia will be monitored with a new EMG device (T4-EMG) from induction of anesthesia until recovery of neuromuscular blockade. Continuous data will be recorded onto an interfaced computer from the T4-EMG monitor during this time period. At the same time, continuous neuromuscular data will be recorded onto the computer from an AMG device (TOF-Watch, the "established standard" for clinical use) which is attached to the same arm. The applicability (ease of use, equipment need, etc.), repeatability (precision or internal consistency), and performance (agreement with established standard, bias) of the T4-EMG compared to the AMG will be determined during onset and recovery of neuromuscular blockade.

44 patients presenting for elective surgical procedures with an expected duration greater than 60 minutes will be enrolled in this study. ASA I to III patients requiring neuromuscular blockade in the operating room will be eligible for enrollment. Anesthetic management will be standardized.

Upon arrival to the operating room, neuromuscular monitoring surface electrodes will be applied. All monitoring will be conducted while the patient is under general anesthesia for the surgical procedure. Surface electrodes (non-invasive EKG electrodes) will be placed on the cleansed skin over the ulnar nerve of the available arm near the wrist. The electrodes will be connected by leads to a peripheral nerve stimulator (TOF-Watch). When the nerve stimulator is activated, the response to stimulation will be measured simultaneously by the AMG (TOF-Watch-acceleration of contraction of the adductor pollicis-thumb) and the EMG (T4-EMG-electrical activity of the adductor pollicis-thumb) devices. Therefore, the TOF-Watch will serve as nerve stimulator for both study groups. The transducer of the AMG device will be placed on the thumb of the corresponding hand. A 75-150g preload (via the Hand adapter) will be applied as per standard recommendations. After induction of anesthesia, but before administration of rocuronium, calibration, supramaximal stimulation, and stable baseline will be achieved for the TOF-Watch as suggested by the GCRP guidelines.

The T4-EMG will be placed on the same arm as the AMG device, with sensing electrodes attached to the surface of the thenar eminence (base of the thumb). A second sensing lead, used to detect the delivery of an electrical stimulating pulse, will be placed over the stimulating leads of the AMG device. This sensing lead will only be used to trigger data acquisition in the T4-EMG, and has no direct connection to the patient, nor any electrical feedback connection that alters the function of the AMG. After a satisfactory level of stimulation and response has been obtained for the TOF-Watch, the T4-EMG device will be turned on, and the impedance of the thenar sensing leads will be measured. The trigger sense will be engaged, and further baseline stimuli will be delivered via the AMG (TOF-Watch). Data simultaneously collected from the thenar sensing leads will be inspected on the T4-EMG display, and fine adjustment of electrode positioning and stimulus intensity may be made to optimize the evoked myoelectric response from the patient. At the conclusion of the setup procedure, all settings of the AMG and the T4-EMG will be held constant for the remainder of the surgery.

After these baseline data are collected (average time 5 minutes), the neuromuscular blocking agent (NMBA) will be administered. Data relating to onset (a TOF ratio decreases from 1.0 to 0.3 or less on the AMG device display), maintenance (the TOF ratio is less than 0.3 and constant on the AMG device display), and reversal (an increase in the TOF ratio from 0.1 to 0.9 or above) will be recorded. Monitoring will continue until full recovery of neuromuscular function is noted (a TOF ratio of at least 0.9 or greater on the AMG device display). At this time, the anesthesia agents will be turned off and the patient awakened and extubated. Patients' trachea may extubated before achieving a TOF ratio of 0.9 if they awaken before this time, as per usual clinical routine determined by the clinician.

研究设计

研究类型
Observational
观察模型
Case Control
时间视角
Prospective

入排标准

年龄范围
18 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • American Society of Anesthesiologists Status I to III patients requiring neuromuscular blockade in the operating room will be eligible for enrollment

排除标准

  • presence of an underlying neuromuscular disease; 2) use of drugs known to interfere with neuromuscular transmission (antiseizure medications, anticholinesterases, magnesium sulfate); 3) presence of renal or hepatic disease; or 4) procedures preventing access to at least one of the upper extremities.

结局指标

主要结局

Train-of-four (TOF)ratio

时间窗: TOF ratios will be measured for the duration of the operation, approximately 3 hours

Train-of-four ratios during recovery of neuromuscular blockade will be compared between the AMG and EMG devices (at a TOF ratio of 0.6, 0.7, 0.8, and 0.9.)

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Glenn Murphy

Director, Clinical Research

NorthShore University HealthSystem

研究点 (1)

Loading locations...

相似试验