A Registry-based, Multicenter, International, Post Market Follow-up Study to Monitor the Safety, Performance and Usability of Occlutech Accessory Medical Devices:Occlutech Delivery Set (ODS), Occlutech Pistol Pusher (OPP), Occlutech Occlusions-Pusher (OOP), Occlutech Sizing Balloon (OSB) Used During to Implantation Procedures of Cardiac Implant Devices
试验速览
- 阶段
- 不适用
- 状态
- 招募中
- 入组人数
- 685
- 试验地点
- 35
- 主要终点
- Occurence of safety events
研究概览
简要总结
The registry is an international, multicenter, non-randomized, non-invasive study to assess the safety, performance and usability of the Occlutech Accessories "Occlutech Delivery Set (ODS), Occlutech Pistol Pusher (OPP), Occlutech Occlusions-Pusher (OOP) and Occlutech Sizing Balloon (OSB)" used for implantation procedures (catheter-based interventions) of cardiac implants via completing surveys (questionnaires) for the accessory medical devices by the investigators.
详细描述
The registry is an international, multicenter, non-randomized, non-invasive study to assess the safety, performance and usability of the Occlutech Accessories "Occlutech Delivery Set (ODS), Occlutech Pistol Pusher (OPP), Occlutech Occlusions-Pusher (OOP) and Occlutech Sizing Balloon (OSB)" used for implantation procedures (catheter-based interventions) of cardiac implants via completing surveys (questionnaires) for the accessory medical devices by the investigators.
A survey (questionnaire) of each accessory medical device should be completed by investigator in order to assess safety of the accessory by success of implantation procedure, occurrence of adverse events during implantation procedure or as late term effects resulting from implantation procedure, user harm related to the accessory, procedure, reported device deficiencies related to the accessory. The Surveys (questionnaires) also include questions related to performance, usability and compatibility with devices and other accessories. Subjects should be treated according to instructions-for-use of the implants and accessories and according to clinical routine. The devices must have been used exclusively by physicians who are experienced in cardiac catheterization techniques and who are experienced in using the products in the process of interventional operations.
研究设计
- 研究类型
- Observational
- 观察模型
- Other
- 时间视角
- Other
入排标准
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Inclusion Criteria depend exclusively on the requirements outlined in the applicable Instruction for Use for accessory medical devices and cardiac implant devices.
- •All subjects who underwent implantation procedure with an Occlutech accessory medical device and cardiac implants can be included
排除标准
- •Exclusion Criteria depend exclusively on the requirements outlined in the applicable Instruction for Use and if applicable in the corresponding protocol of the investigation on the Occlutech implant devices.
结局指标
主要结局
Occurence of safety events
时间窗: 6 months
The primary safety endpoint is defined as the rate of incidences of (peri-) procedural adverse events / rate of (serious) adverse device effects ((S)ADEs) during implantation or as late effects of implantation procedure. A serious adverse device effect (SADE) is defined as an event that is clearly caused by the device such as: * device dislocation (during the procedures with OPP, OOP,ODS) * embolization related with procedure and accessories * Late effect of implantation procedure: damage to the vessels and heart caused by the accessories * any circumstances that require device removal related with procedure or accessories used during the implantation * Signs of thrombosis
次要结局
- Performance, usability:(6 months)
