The Effect of Auricular Vagus Nerve Stimulation on EEG and EMG Measurement in Healthy Persons

Istanbul Gelisim University1 个研究点 分布在 1 个国家目标入组 90 人开始时间: 2021年12月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
90
试验地点
1
主要终点
Maximum hand grip strenght (kg) - before auricular vagus nerve stimulation

研究概览

简要总结

The investigators aimed to divide the healthy individuals aged between 18-45 years, included in our study, into three groups as bilateral, unilateral-right and unilateral-left Auricular Vagus Nerve Stimulation (VNS). The investigators planned to examine the effects of vagal nerve stimulation applied to each group with superficial EMG and EEG measurements before and after.

Auricular vagus nerve stimulation has effects on cerebral activity. Therefore, this effect will be evaluated with EEG. In addition, whether there is a secondary peripheral effect will be examined by EMG method.

Changes to be detected in EEG and EMG in healthy individuals may give an idea about the use of auricular vagus nerve stimulation in patients.

In this study, healthy individuals between the ages of 18-45, who do not have any chronic diseases and who do not have to use any medication regularly will be included in all three groups. Due to the superficial EMG measurement method the investigators used, those who have orthopedic problems in the upper extremity (shoulder, elbow, wrist and fingers) or have a history of surgical operation in the upper extremity, however, any systemic disease such as diabetes, gout, chronic kidney failure, rheumatoid arthritis, thyroid diseases individuals will be excluded from the study in all three groups.

详细描述

Superficial EMG measurement will be made with BIOPAC EMG (Biopac systems, Santa Barbara, CA, USA). Dominant and non-dominant wrist extensor muscle electromyography will be performed with the BIOPAC (Biopac Systems, Santa Barbara, CA, USA) electromyography device and hand grip strength wiil be measured simultaneously with the hand dynamometer of the same device.

A single channel will be used for electromyography measurement , which was taken via surface electrodes (Ag-Cl) over the extensor wrist muscle; the ulnar styloid process will be selected for the ground electrode. Electrodes on the muscle will be placed about 0.5 cm apart. The measurement will be taken in the standard measurement position of the hand dynamometer, with 0° shoulder flexion, 0° shoulder abduction, 90° elbow flexion and forearm in the midline position, in the sitting position, during for 5 seconds of maximum grip.The measurement will be repeated 3 times and root mean square (RMS) calculations will be made with the MATLAB software.

The bioelectrical activity of the brain will be measured with the EMOTIV EPOC+ EEG device.

Auricular Vagus Nerve Stimulation will be performed with a device called VAGUSTIM. Auricular Vagus Nerve Stimulation will be performed for 20 minutes with a frequency of 10 Hz and a pulse width of 300 µs.

The investigators are planning to examine the effects of vagal nerve stimulation, which the investigators will apply to each group using different methods, by examining the effects of vagal nerve stimulation before and after the superficial EMG and EEG measurements as well as the first test and post test measurement in each group, and at the same time, the investigators are planning to evaluate the results the investigators obtained by comparing the results between the groups in all three groups.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Basic Science
盲法
None

入排标准

年龄范围
18 Years 至 45 Years(Adult)
性别
All
接受健康志愿者
是

入选标准

  • •Between the ages of 18-45,
  • •Who do not have any chronic diseases
  • •Who do not have to use any medication regularly

排除标准

  • •Due to the superficial EMG measurement method we used,
  • •Those who have orthopedic problems in the upper extremity (shoulder, elbow, wrist and fingers) or have a history of surgical operation in the upper extremity,
  • •Systemic disease such as diabetes, gout, chronic kidney failure, rheumatoid arthritis, thyroid diseases individuals .

研究组 & 干预措施

Bilateral Auricular Vagus Nerve Stimulation

Experimental

Vagus nerve stimulation is applied to this group from both ears.

干预措施: Bilateral Auricular Vagus Nerve Stimulation will be performed with a device called VAGUSTIM. (Device)

Unilateral - Right Auricular Vagus Nerve Stimulation

Experimental

In this group, vagus nerve stimulation is performed only from the right ear.

干预措施: Unilateral-Right Auricular Vagus Nerve Stimulation will be performed with a device called VAGUSTIM. (Device)

Unilateral - Left Auricular Vagus Nerve Stimulation

Experimental

In this group, vagus nerve stimulation is performed only from the left ear.

干预措施: Unilateral-Left Auricular Vagus Nerve Stimulation will be performed with a device called VAGUSTIM. (Device)

结局指标

主要结局

Maximum hand grip strenght (kg) - before auricular vagus nerve stimulation

时间窗: The measurements will be recorded during 30 sec intervals 3 times 5 sec maximum isometric hand grip - before auricular vagus nerve stimulation

Maximum hand grip strenght will be taken simultaneously surface EMG. (dominant and non dominant hand, before auricular vagus nerve stimulation)

Electroencephalography- Frequency bands(Hz)- after auricular vagus nerve stimulation

时间窗: The bioelectrical activity of the brain will be measured with the EMOTIV EPOC+ EEG device for ten minutes. (after auricular vagus nerve stimulation

The bioelectrical activity of the brain will be measured with the EMOTIV EPOC+ EEG device for ten minutes. (after auricular vagus nerve stimulation)

Mean activitation value of the wrist extensor group muscles (mV) - before auricular vagus nerve stimulation

时间窗: The measurements will be recorded during 30 sec intervals 3 times 5 sec maximum isometric hand grip-before auricular vagus nerve stimulation

The mean extensor muscle activitation will be taken during maximum isometric contraction through extensor muscles motor point of the wrist, and dominant and non-dominant hand grip strength will be measured simultaneously with the hand dynamometer of the same device. (before auricular vagus nerve stimulation)

Maximum hand grip strenght (kg) - after auricular vagus nerve stimulation

时间窗: The measurements will be recorded during 30 sec intervals 3 times 5 sec maximum isometric hand grip - after auricular vagus nerve stimulation

Maximum hand grip strenght will be taken simultaneously surface EMG. (dominant and non dominant hand, after auricular vagus nerve stimulation)

Electroencephalography- Frequency bands(Hz)- before auricular vagus nerve stimulation

时间窗: The bioelectrical activity of the brain will be measured with the EMOTIV EPOC+ EEG device for ten minutes. (before auricular vagus nerve stimulation

The bioelectrical activity of the brain will be measured with the EMOTIV EPOC+ EEG device for ten minutes. (before auricular vagus nerve stimulation)

Mean activitation value of the wrist extensor group muscles (mV) - after auricular vagus nerve stimulation

时间窗: The measurements will be recorded during 30 sec intervals 3 times 5 sec maximum isometric hand grip - -after auricular vagus nerve stimulation

The mean extensor muscle activitation will be taken during maximum isometric contraction through extensor muscles motor point of the wrist, and dominant and non-dominant hand grip strength will be measured simultaneously with the hand dynamometer of the same device. (after auricular vagus nerve stimulation)

次要结局

未报告次要终点

研究者

发起方
Istanbul Gelisim University
申办方类型
Other
责任方
Principal Investigator
主要研究者

Gulsah Konakoglu

Lecturer