Treatment of Intracranial Aneurysms using a vascular Reconstruction Assist device: a randomised controlled trial of self expanding stent (conventional mesh density) plus coiling versus coiling +/- temporary assist techniques

othian University Hospitals Division (UK)0 个研究点目标入组 550 人开始时间: 2011年4月7日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
550

研究概览

简要总结

暂无简介。

研究设计

研究类型
Interventional

入排标准

性别
All

入选标准

  • 1. Age range 18-70 (evidence that procedural risk for stent placement in over 70 is 4 fold greater and saccular aneurysms are extremely uncommon under 18)
  • 2. Patient world federation of neurosurgeons (WFNS) Grade 0-2 [anticipated most patients recruited will be 0]
  • 3. Aneurysm judged suitable for treatment by coiling plus or minus the stent assistance and operator content to use/not use stent according to randomisation treatment allocation result
  • 4. Aneurysm greater than or equal to 8mm in maximal diameter, with aneurysm neck greater than 4mm or dome to neck ratio less than 2:1, but less than 25mm in size. If target aneurysm previously treated by coiling the recurrence must have a maximal diameter in this range
  • 5. If a patient presents with subarachnoid haemorrhage (SAH) and staged treatment with delayed stenting is judged appropriate due to aneurysm size/neck width then the patient is eligible

排除标准

  • 1. Does not meet aneurysm size/neck characteristics outlined in inclusion criteria
  • 2. Less than18 years or more than 70 years of age
  • 3. Pregnant
  • 4. Unable to consent for themselves
  • 5. Non-saccular aneurysm - e.g. blister, fusiform or definitely dissecting aneurysm
  • 6. Subarachnoid hemorrhage (SAH)/intracerebral haemorrhage from another aneurysm or intracranial lesion within last 28 days
  • 7. Major surgery within last 30 days (or any other medical situation where dual antiplatelet therapy is contraindicated in the opinion of the responsible neurovascular team)
  • 8. Intention to deploy flow diverting device/construct as primary aneurysm treatment
  • 9. More than one aneurysm requiring treatment in current procedure
  • 10. Target or a nearby aneurysm has had previous stent treatment such that a Vascular Reconstruction Device [VRD i.e. a stent] is already across all or greater than 1/3 of the neck of the target aneurysm
  • 11. Medical or surgical co-morbidity such that the patient?s life expectancy is less than 1 year
  • 12. The patient has been previously randomised into this trial
  • 13. Patient has been randomised into another trial of an endovascular device for aneurysm treatment within the last 6 months
  • 14. Deployment of stent judged essential to treat the aneurysm