NCT06932133招募中不适用

Breast Point-of-Care Ultrasound Examination Trial

Region Skane1 个研究点 分布在 1 个国家目标入组 600 人开始时间: 2025年4月7日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
招募中
发起方
Region Skane
入组人数
600
试验地点
1
主要终点
The area under the receiver operating characteristic curve (AUC) for the intervention, compared to that of the comparator

研究概览

简要总结

The high cost of diagnostic equipment, limited expertise, and inadequate infrastructure are major barriers to early breast cancer diagnosis in low- and middle-income countries. Point-of-care ultrasound (POCUS) offers a relatively low-cost, portable solution that, when combined with artificial intelligence (AI)-driven image analysis, has the potential to significantly expand access to breast assessment in these settings. The purpose of this study is to evaluate the performance of POCUS for women with focal breast symptoms and to assess the performance of AI to analyze POCUS images. The study will be divided in two parts: a prospective interventional study and a retrospective multicase multireader study.

详细描述

In this trial we want to understand if the use of POCUS is non-inferior to Standard of Care (SoC) and if the combination of POCUS AI can reach non-inferior performance to that of breast radiologists. There is a need for breast diagnostic tools in underserved countries since late-stage diagnosis is a major cause of the high breast-cancer mortality in low-and middle-income countries. Showing that POCUS can be sufficient for an assessment of focal breast symptoms can provide evidence for a broader use. Also, enabling automated interpretation using AI can add to the value of this low-cost and accessible solution. The first part of the trial is a prospective open-label accuracy study with paired design. The intervention of POCUS as a targeted diagnostic method for women with focal breast complaints will be compared with SoC. We will also be able to compare POCUS with the individual components of SoC (mammography and standard ultrasound) and retrospectively with POCUS AI. The second part of the trial is a single-blinded retrospective paired mulitcase multireader study. In this part we can directly assess POCUS and POCUS AI without the influence of mammography and benchmark to a larger group of radiologists and in addition compare with standard ultrasound

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
Female
接受健康志愿者
否

入选标准

  • •Women (≥18 years of age) referred to diagnostic imaging with a suspicion on malignancy

排除标准

  • •Individuals unable to comprehend the study information due to language barriers or cognitive impairments.

研究组 & 干预措施

Intervention

Experimental

干预措施: Point-of-care ultrasound (Diagnostic Test)

结局指标

主要结局

The area under the receiver operating characteristic curve (AUC) for the intervention, compared to that of the comparator

时间窗: From the last enrolled participant to the end of one-year follow up

1. The AUC of POCUS compared to SoC 2. The AUC of AI compared to average radiologists on POCUS

次要结局

  • The performance of POCUS and POCUS AI(From the last enrolled participants to the end of one year follow up)