跳至主要内容
临床试验/NCT04059575
NCT04059575已完成不适用

What Kind of Kinesio Taping Material Should be Used to Decrease the Injury Risk Better

Guven Health Group1 个研究点 分布在 1 个国家目标入组 32 人开始时间: 2020年9月24日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
32
试验地点
1
主要终点
vertical jump

研究概览

简要总结

Research design: The study protocol was approved and required permissions were taken from related tennis club officials, and a written consent was obtained from all the participants' parents about the study. Thirty-three young tennis players aged between 9 and 12 were included in our study. Assessment were done bare (no tape), after 45 min of performance plus kinesio taping application (PP application) and after 45 min of gold text FP kinesio taping application (GT application). We were randomly taped with either PP or GT taping applications using an online random allocation software program (GraphPad Software QuickCalcs, GraphPad Software Inc., La Jolla, CA, USA). Thirty min of rest was given between 2 taping applications after the removal of the first tape. One participant was not able to complete the second taping procedure. PP and GT taping applications were done by using kinesio taping muscle facilitation techniques to Quadriceps and Gastrosoleus muscles. I-shaped tape with a tension of 10-35% was used for muscle facilitation. All patients were assessed by an experienced physiotherapist, and the tapings were done by another experienced physiotherapist in order to provide a single blind structure of the study.

详细描述

Participants: Thirty-three young tennis players aged between 9 and 12 yrs were recruited in the study. The exclusion criteria included those (a) with soft tissue or bone problems affecting lower extremity, (b) who had acute inflammation affecting lower extremity region, (c) had scoliosis, (d) who had undergone any orthopedic surgery, (e) who had defined any pain or painful area at lower extremities and (f) who were obese (BMI>30 kg/m2).

Assessments: Thermal analysis was done for risk of injury including both lower extremities. Quadriceps muscle was chosen from upper leg and gastro soleus muscle was chosen from lower leg region for thermal analysis. The thermo graphic assessment was performed by using FLIR E5 (FLIR Systems AB, Sweden) thermal camera in order to evaluate which muscles had the highest thermal activity while maintaining stable upright posture. The part of muscle with more activation (greater heat) was measured by the thermo graphic camera and the heat was recorded in centigrade. Each participant was thermo graphically evaluated in the same room (ambient temperature, 21°C) and participants were left for 10-20 minutes to 'acclimatize' to the thermographic imaging environment FLIR E5 Thermal Camera, with a resolution of 120 x 90 pixels was used for thermal imaging and the Color Palette iron was chosen for displaying the images. It is indicated that IR imaging may be a reliable and valid measure of treatment outcomes with clinical utility and sensitivity

The power analysis indicated that 33 participants for total were needed with 80 % power and a 5 % type 1 error. The power analysis of our study showed a power of 80% with tissue temperature as the primary outcome. The data were analyzed using statistical software (SPSS version 18, Inc., Chicago, IL, USA). All the statistical analyses were set a priori at an alpha level of p<0.05. The tests for homogeneity (Levene's test) and normality (Shapiro-Wilk) were used to determine the appropriate statistical methods. According to the test results, nonparametric Friedman test was used for comparisons between baseline, first taping and last taping. Wilcoxon test was used for possible differences which may occur between taping applications in order to identify the application that provided the difference. Parametric test assumptions were not possible due to small sample size and inhomogeneous parameters.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Crossover
主要目的
Prevention
盲法
Single (Participant)

盲法说明

Thirty-three young tennis players aged between 9 and 12 yrs were recruited in the study. The exclusion criteria included those (a) with soft tissue or bone problems affecting lower extremity, (b) who had acute inflammation affecting lower extremity region, (c) had scoliosis, (d) who had undergone any orthopedic surgery, (e) who had defined any pain or painful area at lower extremities and (f) who were obese (BMI>30 kg/m2

入排标准

年龄范围
9 Years 至 12 Years(Child)
性别
All
接受健康志愿者
是

入选标准

  • •at least playing tennis 2 years
  • •to be between 9 and 12 years
  • •no any sport activity-only tennis
  • •to be a volunteer

排除标准

  • •with soft tissue or bone problems affecting lower extremity,
  • •who had acute inflammation affecting lower extremity region,
  • •had scoliosis,
  • •who had undergone any orthopedic surgery,
  • •who had defined any pain or painful area at lower extremities and
  • •who were obese (BMI>30 kg/m2).

研究组 & 干预措施

PERFORMANCE PLUS

Experimental

performance plus better than GOLD TEX

干预措施: Kinesio Taping (Performance Plus) (Other)

GOLD TEX

Active Comparator

GOLD TEX better than performance plus

干预措施: Kinesio taping (Gold Tex) (Other)

结局指标

主要结局

vertical jump

时间窗: 1 hours

A vertical jump test was performed before and after the application of Kinesio taping® to their quadriceps and gastrocnemius muscles according to Kase's recommendations. The height and flight time data was collected using a portable optical timing system (Optojump Next; Microgate, Bolzano, Italy) during a counter movement jump. Mean maximum jump height and flight time were averaged from three attempts. Two-way repeated measures ANOVAs were used to assess the influence taping condition on vertical jump performance.

termal analysis

时间窗: 2 hours

Quadriceps muscle was chosen from upper leg and gastro soleus muscle was chosen from lower leg region for thermal analysis. The thermo graphic assessment was performed by using FLIR E5 (FLIR Systems AB, Sweden) thermal camera in order to evaluate which muscles had the highest thermal activity while maintaining stable upright posture. The part of muscle with more activation (greater heat) was measured by the thermo graphic camera and the heat was recorded in centigrade. Each participant was thermo graphically evaluated in the same room (ambient temperature, 21°C) and participants were left for 10-20 minutes to 'acclimatize' to the thermographic imaging environment FLIR E5 Thermal Camera, with a resolution of 120 x 90 pixels was used for thermal imaging.

次要结局

  • age(through study completion, an average of 8 weeks)

研究者

发起方
Guven Health Group
申办方类型
Other
责任方
Principal Investigator
主要研究者

GUL BALTACI

PROFESSOR, PT, PH.D

Guven Health Group

研究点 (1)

Loading locations...