临床试验/NCT02700425
NCT02700425已完成不适用

His Bundle Pacing Versus Coronary Sinus Pacing for Cardiac Resynchronization Therapy

University of Chicago16 个研究点 分布在 1 个国家目标入组 41 人开始时间: 2016年5月17日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
41
试验地点
16
主要终点
Change in QRS Duration

研究概览

简要总结

The goal of this study is to compare the effectiveness of pacing from a physiologic His bundle (HB) lead position versus with the standard coronary sinus (CS) lead position in subjects with heart failure undergoing cardiac resynchronization therapy (CRT). While placement of left ventricular leads via the coronary sinus has anatomic limitations, we hypothesis that the achievement of QRS narrowing with His bundle capture will be superior for improving systolic function by echocardiographic indices (ejection fraction and strain) and quality of life and decreased rehospitalization and mortality.

详细描述

This is a randomized, single-blinded study of 40 patients to a strategy of HB pacing versus CS pacing, and remain blinded to their treatment allocation. Both treatment options use standard-of-care, FDA-approved devices. The distinction is only in the allocation toward HB pacing and CS pacing. Treating physicians will be aware of assignment in order to facilitate routine device follow-up. Echocardiographic and electrocardiographic evaluation will also be performed in a blinded manner.

Cross-over is permitted between treatment group allocation if:

  • CS lead cannot be placed due to difficult cannulation of the CS, limited branches at the posterolateral or lateral wall, or phrenic nerve capture. These subjects may then cross-over to HB pacing.
  • HB pacing subjects may cross-over if HB lead cannot be positioned with adequate stability and reasonable pacing output, or if QRS width does not narrow by at least 20% or to a QRS width of ≤ 130 msec.

Implant procedure will be per routine percutaneous access, as is standard for pacemaker and ICDs. All subjects will receive an FDA-approved cardiac resynchronization therapy pacemaker or defibrillator device, as per standard of care outlined for the subject. In order to facilitate optimal lead placement, arterial access for levo-phase CS angiography and/or LV septal mapping to characterize site of bundle-branch block may also be performed, at the discretion of the implanting physician per his/her standard practice.

Follow-up will be performed at 2 weeks post-implant for incision check and device interrogation as is standard of care. In addition, routine device and clinical follow-up will be scheduled at 1, 3, 6, and 12 months. Electrocardiography (ECG) will be performed pre-implant, prior to hospital discharge, at 3 months, 6 months, and 12 months. Echocardiography will be performed pre-implant and 6 months to evaluate for change in LVEF, chamber dimension, and wall motion with strain imaging as is standard of care in the treatment of patients with advanced heart failure. NYHA functional class and quality of life (utilizing the Kansas City Cardiomyopathy Questionnaire) will be assessed pre-implant and at 6 months.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Single (Participant)

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients at least 18 years of age
  • LV systolic dysfunction with LVEF ≤ 35%
  • Evidence of intraventricular conduction delay with QRS duration > 120 msec
  • NYHA Class II, III, and ambulatory Class IV heart failure with either ischemic or nonischemic cardiomyopathy and patients with NYHA Class I symptoms and ischemic cardiomyopathy
  • Left ventricular ejection fraction (LVEF) ≤ 35%, sinus rhythm (SR), left bundle-branch block (LBBB) morphology, and QRS duration ≥ 150 msec, and NYHA Class II, III, or ambulatory Class IV patients on goal-directed medical therapy (GDMT) [Class I]
  • LVEF ≤ 35%, SR with LBBB with QRS 120-149 msec on GDMT [Class IIa]
  • LVEF ≤ 35%, SR with non-LBBB with QRS ≥ 150 msec on GDMT [Class IIa]
  • LVEF ≤ 35%, in AF if medication or AV nodal ablation will allow near 100% pacing [Class IIa]
  • LVEF ≤ 35% undergoing new or replacement device with anticipated >40% ventricular pacing on GDMT [Class IIa]
  • LVEF ≤ 30%, ischemic etiology of HF, SR with LBBB ≥ 150 msec and NYHA Class I symptoms on GDMT [Class IIb]
  • LVEF ≤ 35%, SR with non-LBBB with QRS 120-149 msec, NYHA Class III/ambulatory Class IV HF on GDMT [Class IIb] LVEF ≤ 35%, SR with non-LBBB with QRS ≥ 150 msec, NYHA Class II HF on GDMT [Class IIb]

排除标准

  • Existing CRT device
  • Inability of patient capacity to provide consent for themselves either due to medical or psychiatric comorbidity
  • Pregnancy
  • Participation in other trials
  • Difficulty with follow-up

结局指标

主要结局

Change in QRS Duration

时间窗: baseline and 12 months

Change in QRS duration as measured by electrocardiography

Change in Left Ventricular Ejection Fraction (LVEF)

时间窗: baseline and 6 months

Change in left ventricular ejection fraction (LVEF) as measured by echocardiography in a blinded core lab.

Time to First Cardiovascular Hospitalization or Death

时间窗: Through study completion, an average of 12 months.

Time to first cardiovascular hospitalization or death in months

次要结局

  • Time to First Cardiovascular Rehospitalization(Through study completion, an average of 12 months)
  • Time to First Treated Ventricular Arrhythmia/Ventricular Tachycardia (VT/VF)(Through study completion, an average of 12 months)
  • New York Heart Association (NYHA) Functional Class Change(baseline, 6 months, and 12 months)
  • Quality of Life Change by Kansas City Questionnaire (KCCQ)(baseline and 12 months)