跳至主要内容
临床试验/NCT00289068
NCT00289068已完成不适用

Determination of Surgical Efficacy and Most Efficient Surgical Parameters for Use With the 2.2, 2.8, and 3.0mm Phacoemulsification Sleeves Used With the Alcon Infinity 1.1mm ABS Flared Tip

University of Oklahoma1 个研究点 分布在 1 个国家目标入组 44 人开始时间: 2006年1月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
44
试验地点
1
主要终点
Total surgical time, fluid volume, energy used to extract the cataract, post-operative cell and flare and corneal clarity

研究概览

简要总结

Incision size in cataract surgery is related to induced surgical astigmatism, chamber stability, and surgical efficiency. Sleeves of different diameters change the size of the surgical incision and amount of fluid allowed into the eye during the surgical procedure for a given set of surgical parameters. Optimization of surgical parameters requires review of surgical efficiency including: fluid usage, energy usage, and total surgical time. With optimized surgical parameters recommendations can be made to increase the efficiency and safety of cataract surgery.

详细描述

No scientific data has been presented comparing the surgical efficiency of the 2.2, 2.8, and 3.0 mm diameter phacoemulsification sleeves for the Alcon Infinity 1.1 mm flare abs tip or the changes in surgical parameters which optimize their performance. Fifty patients per sleeve group will undergo standard cataract extraction with documentation of surgical parameters used for each group. The goal of the study is to determine the most efficient surgical settings for each sleeve diameter and determine statistically the surgical parameters which optimize the use of each phacoemulsification sleeve.

Purpose: The goal of the study is to determine the most efficient surgical settings for each sleeve diameter and determine statistically the surgical parameters which optimize the use of each phacoemulsification sleeve.

Design: The study is designed to allow for scientific evaluation and publication of efficiency parameters using phacoemulsification sleeves of 2.2, 2.8, and 3.0 mm. The proposed study is a prospective nonrandomized clinical investigation of 50 patients per sleeve group.

Methods: Data gathered at the time of surgery will include standard surgical parameters including: Total surgical time, total phacoemulsification/torsional time/power, total volume of infusion fluid, aspiration level, and vacuum level. Post-operative data will include: Post-op day one and week three corneal clarity (clear, would edema, central edema), anterior chamber cell seen in a 2mm 16x magnified slit-lamp biomicroscopic view focused in the aqueous humor (Grade 0 = 0 cells, 1 = up to 10 cells, 2 = 10 to 20 cells, 3 = 20 to 30 cells, 4 = too numerous to count), and uncorrected and/or best corrected visual acuity.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 100 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • requiring cataract surgery

排除标准

  • 未提供

结局指标

主要结局

Total surgical time, fluid volume, energy used to extract the cataract, post-operative cell and flare and corneal clarity

时间窗: 2 years

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...