NCT00732225已完成3 期
A Prospective, Non-randomized Comparison of DisCoVisc to Dispersive and Cohesive Ophthalmic Viscosurgical Devices (OVDs) in Non-eventful Cataract Surgery
适应症
试验速览
- 阶段
- 3 期
- 状态
- 已完成
- 入组人数
- 173
- 试验地点
- 2
- 主要终点
- Percent Loss of Endothelial Cells
研究概览
简要总结
A comparison of the ability of DisCoVisc to that of other Opthalmic Viscosurgical Devices (OVDs) (DuoVisc®, BioVisc®, Healon5®, or Amvisc PLUS) regarding endothelial protection and anterior chamber space maintenance during non-eventful cataract surgery.
研究设计
- 研究类型
- Interventional
- 分配方式
- Non Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- Single (Participant)
入排标准
- 年龄范围
- 49 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Unilateral operable cataracts
排除标准
- •Preoperative Endothelial Cell Count (ECC) ≤1500 cells/mm2
- •Intraocular Pressure (IOP) > 21
- •History of ocular inflammation
- •Systemic or ocular diseases affecting corneal endothelium
结局指标
主要结局
Percent Loss of Endothelial Cells
时间窗: 2 months following surgery
Percentage of corneal endothelial cells lost 2 months after surgery as compared to the number of corneal endothelial cells measured before the operation. Corneal Endothelial Cells are measured by counting the number of cells on an image taken by specular microscope.
次要结局
- Aqueous Signs - Corneal Edema(1 day after surgery)
- Aqueous Signs - Aqueous Flare(1 day following surgery)
- Aqueous Signs - Aqueous Cells(1 day following surgery)
- Intraocular Pressure (IOP)(1 day following surgery)
- Physician Survey - Anterior Chamber Dome Maintenance During Anterior Capsulotomy(Time of Surgery)
- Physician Survey - Anterior Chamber Dome Maintenance During Phacoemulsification(Time of Surgery)
- Physician Survey - Anterior Chamber Dome Maintenance During IOL Insertion(Time of Surgery)
研究者
研究点 (2)
Loading locations...
相似试验
已完成
4 期
DisCoVisc Versus DuoVisc, Healon5 and AmVisc PlusCataractNCT00712244Alcon Research112
已完成
4 期
To Compare the Ability of DiscoVisc® OVD to Protect the Corneal Endothelium and Maintain Anterior Chamber Space With Healon® and Amvisc® PLUS During Cataract Surgery.CataractNCT00763360Alcon Research184
已完成
4 期
Comparison of DisCoVisc and Hydroxypropylmethylcellulose 2%Corneal EdemaIntraocular PressureNCT01387620University of Sao Paulo39
已完成
不适用
Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry ReadingsCataractNCT03751033Clinical Research Consultants, Inc.120
已完成
4 期
Comparison of four Ophthalmic viscosurgical devices (OVDs) on Corneal Endothelial Cell Protection during PhacoemulsificatioOphthalmic viscosurgical devices effect on corneal endothelial cell protection during PhacoemulsificationOphthalmic viscosurgical devicesCorneal endothelial cell protectionPhacoemulsificationTCTR20220317002Faculty of Medicine Research fund, Chiang Mai University, Chiang Mai Thailand72
