Prospective, Randomized, Controlled Trial to Evaluate the Effect of Preoperative Penile Traction Therapy on Post-penile Implant Length and Patient Satisfaction
试验速览
- 阶段
- 不适用
- 状态
- 招募中
- 入组人数
- 48
- 试验地点
- 2
- 主要终点
- Penile Length
研究概览
简要总结
The goal of this study is to determine whether or not the use of a penile traction therapy device known as RestoreX prior to implantation of a penile prosthesis can increase the length of the implant used during surgery. The device used in this study is commercially available and has been used successfully to facilitate penile lengthening in patients with diabetes and after a certain type of prostate surgery. Use of the device has not been shown to have any detrimental effects on sexual or overall health.
详细描述
Men with erectile dysfunction (ED) refractory to medical therapies are often recommended to undergo placement of an inflatable penile prosthesis (IPP). However, men commonly report a perceived loss of penile length following IPP implantation. This is likely due to one of several factors, including the underlying disease process which resulted in loss of penile length, effects of aging on penile length (loss of elasticity; increased fibrosis), changes in abdominal physiology (development of pre-pubic fat pad that obscures the penis), and recall bias (incorrect recollection of prior penile length).
Several attempts have been made by investigators to optimize penile length prior to placement of the penile prosthesis, including adjunctive surgical maneuvers (excision of suprapubic fat pad, release of suspensory ligament, direct penile extension), use of injectable materials, and pre-operative use of penile traction therapy (PTT). In a small pilot study of 10 men undergoing IPP, Levine and colleagues recommended the use of the Andropenis PTT ≥2 hrs daily for 2-4 months. At 15 months follow-up, patients achieved a +1.6 cm increase compared to pre-traction stretched length, and +0.9 cm increase following prosthesis implantation. Results from a non-validated satisfaction questionnaire demonstrated that no patients reported loss of length following surgery. Unfortunately, the study did not include a control group, thus limiting the conclusions which may be drawn.
Compared to other options, PTT offers several potential advantages in that it is minimally invasive, does not increase the morbidity of surgery, and has not been shown to result in any long-term side effects. RestoreX is a commercially available PTT device that was developed by the Mayo clinic and has been licensed to PathRight Medical. It has been designated as a Class I device that does not require clinical human trials. The device is currently utilized in 30-minute intervals, with up to 3 sessions performed per day, and has demonstrated efficacy at increasing stretched penile length in patients with postprostatectomy penile shortening and diabetes mellitus.
Given the clinical issue of dissatisfaction with penile length post IPP, the potential role for PTT, and the limited amount of data that are currently available, we seek to perform a clinical trial evaluating the effect of PTT stretched penile length, size of prosthetic implantation at time of surgery, and patient satisfaction following implantation.
The device has two functional aspects. The first is the ability to provide direct traction on the penis. The second is the ability to provide counter-bending forces, to treat conditions such as Peyronie's disease. In the current study, only the direct traction aspects of the device will be investigated. Men randomized to treatment will be recommended to utilize the device for 30 minutes, 3 times daily for 3 months prior to placement of an IPP, with up to 1.3 additional months to account for variability in surgical timing.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- Male
- 接受健康志愿者
- 否
入选标准
- •Have a documented diagnosis of erectile dysfunction
- •Can provide informed consent
- •Are willing and able to comply with study procedures and visit schedules
- •Are to be scheduled for a planned standard of care implantation of an inflatable penile prosthesis
排除标准
- •Prior ischemic priapism
- •Prior implantation of a penile prosthesis
- •Prior use of any penile traction device
- •Any prior penile surgeries other than circumcision
- •Prior pelvic radiation
- •Current or prior androgen deprivation therapy
- •Active genital infection
- •History of neophallus creation
研究组 & 干预措施
Penile Prosthesis Implantation
Patients with erectile dysfunction presenting for placement of a three-piece inflatable prosthesis who are randomized to the no intervention arm will proceed directly to implantation of a standard-of-care inflatable penile prosthesis at the next available surgical appointment. They will not use the RestoreX penile traction device. They will complete standardized assessments of sexual function and satisfaction before and after placement.
干预措施: Inflatable Penile Prosthesis Implantation (Procedure)
RestoreX and Penile Prosthesis Implantation
Patients with erectile dysfunction presenting for placement of a three-piece inflatable prosthesis who are randomized to the intervention arm will be provided with a RestoreX penile traction device, which they will utilize for three months prior to implantation of a standard-of-care inflatable penile prosthesis. They will complete standardized assessments of sexual function and satisfaction before and after placement, as well as a device use diary.
干预措施: Penile Traction Device (Device)
RestoreX and Penile Prosthesis Implantation
Patients with erectile dysfunction presenting for placement of a three-piece inflatable prosthesis who are randomized to the intervention arm will be provided with a RestoreX penile traction device, which they will utilize for three months prior to implantation of a standard-of-care inflatable penile prosthesis. They will complete standardized assessments of sexual function and satisfaction before and after placement, as well as a device use diary.
干预措施: Inflatable Penile Prosthesis Implantation (Procedure)
结局指标
主要结局
Penile Length
时间窗: At screening to approximately three months after enrollment at the time of penile prosthesis implantation
Change in stretched penile length measured at time of enrollment and intraoperatively at the time of IPP implantation, measured in cm.
Prosthesis size
时间窗: 0-4 months after enrollment at the time of penile prosthesis implantation
Size of inflatable penile prosthesis cylinders placed
Sexual Satisfaction
时间窗: At enrollment and at three-month postoperative follow up.
Change in patient-reported satisfaction with their sexual function from enrollment to final postoperative follow up using the validated IIEF-15 (International Index of Erectile function - 15 item) questionnaire, which has a minimum score of 6 and maximum score of 75 with a larger number indicating improved sexual satisfaction. The change seen in participants assigned to the RestoreX device arm will be compared to the change seen in patients assigned to the control arm.
Incidence of Satisfaction with Penile Length
时间窗: 3-8 months postoperatively
A comparison of the incidence of participants reporting satisfaction with their penile length, expressed as a percentage or all participants within each group, based on participant reporting to an investigator during their surgical follow up.
次要结局
- Compliance with Therapy(0-4 months after enrollment, intervention arm only)
- Incidence of adverse events(0-16 months)
- Patient Satisfaction with Prosthesis Use(3-8 months)
研究者
J. Peter Rubin, MD
Professor and Endowed Chair of Plastic Surgery
University of Pittsburgh