A Single Center Evaluation of AI Enabled SureForm Robotic Stapler (SureformTM) Compared to Conventional Stapler for Colorectal Cancer Procedures
试验速览
- 阶段
- 不适用
- 状态
- 招募中
- 发起方
- 入组人数
- 200
- 试验地点
- 1
- 主要终点
- Anastomotic leak rates
研究概览
简要总结
Robotic-assisted surgeries are especially valuable for colorectal pathologies because they offer better vision and control for surgical manipulation given the narrow operative region within the pelvis .Some of the iatrogenic risk factors associated with higher post-operative adverse events following colorectal surgeries are surgeon experience' and hospital case load'. In order to mitigate these factors, surgical staplers have gained preference amongst surgeons due to their reproducible results and ease of learning At present there are only two methods of creating an anastomosis: hand-sewn technique using sutures or surgical staplers. Surgical staplers have been shown to be as effective as hand-sewn techniques for colorectal anastomoses However, anastomotic strictures can be bothersome for patients and the rate of stricture is fourfold higher for stapled anastomoses than for those that are hand sewn in colorectal anastomoses . Additionally, overzealous or incorrect stapling could also result in hemostasis or ischemia One of the most dreaded adverse events of colorectal resection is anastomotic leakages followed, in decreasing severity, by post-operative bleeding and ileus. Because of the severity of adverse events associated with an anastomotic leak, it is important to detect it early and provide early management for the same. However, diagnosis of anastomotic leakage is commonly a symptomatic diagnosis based on development of gas, purulent or fecal discharge from the drain, purulent discharge from the rectum, pelvic abscess or peritonitis. Such severe symptoms further complicate the post-operative recovery and lengthen the hospital stay. Interestingly, it has been
reported that anastomotic leaks were more often diagnosed late in the postoperative period and more often after hospital discharge, or 12 days postoperatively . Anastomotic leakage rates vary from the colon to the rectum, with much higher rates in the rectum. Because of the severity of adverse events associate with an anastomotic leak, there is a pressing need for new techniques for prevention of anastomotic leakages .
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 80 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •A. Subjects, 18 to 90 years B. Subjects who will undergo Planned robotic-assisted surgery or laparoscopic surgery (as the primary treatment) for non-metastatic colorectal cancer where staplers are utilized for transection and/or creation of anastomosis
排除标准
- •A. Emergency Surgery for non-metastatic colorectal cancer B. Subjects who are being treated for recurrent colorectal cancer C. Subjects who will require extensive dissection to release adhesions or with advanced cancer which may result in anastomotic leak and/or bleeding unrelated to the stapler D. Subjects who have perforated, obstructing or locally invasive neoplasm (T4b) E. Subjects who have major concomitant abdominal or pelvic procedures (e.g. hepatectomies, incisional ventral hernia repair, nephrectomies, hysterectomy) planned along with surgery for colorectal cancer
研究组 & 干预措施
Laparoscopic Surgery Group (Comparator Arm)
Subjects undergoing laparoscopic colorectal cancer surgery using conventional laparoscopic staplers for bowel transection and/or creation of anastomosis.
干预措施: AI-enabled SureForm™ Robotic Stapler (Device)
Laparoscopic Surgery Group (Comparator Arm)
Subjects undergoing laparoscopic colorectal cancer surgery using conventional laparoscopic staplers for bowel transection and/or creation of anastomosis.
干预措施: Conventional Laparoscopic Stapler (Device)
Robotic-Assisted Surgery Group (Intervention Arm)
Subjects undergoing robotic-assisted colorectal cancer surgery where AI-enabled SureForm™ Robotic.Stapler is used for bowel transection and/or creation of anastomosis.
干预措施: AI-enabled SureForm™ Robotic Stapler (Device)
Robotic-Assisted Surgery Group (Intervention Arm)
Subjects undergoing robotic-assisted colorectal cancer surgery where AI-enabled SureForm™ Robotic.Stapler is used for bowel transection and/or creation of anastomosis.
干预措施: Conventional Laparoscopic Stapler (Device)
结局指标
主要结局
Anastomotic leak rates
时间窗: 24 MONTHS
• Technological performance of stapler- Angle of stapler fire, Percent of cases with firing rate \>45 degrees, Utility of AI Enabled (Smartfire) decision making- Clamp rates, fire rates
次要结局
- Operative time(24 MONTHS)
研究者
Mohan Ramchandani
Consultant Gastroenterology
Asian Institute of Gastroenterology, India
