CTRI/2024/12/078766尚未招募不适用
Comparison between mainstream end tidal carbon dioxide monitoring v/s arterial pressure of carbon dioxide monitoring post extubation in patients on non invasive ventilation on timely detection of extubation failure.
未提供1 个研究点 分布在 1 个国家目标入组 60 人开始时间: 2025年1月15日最近更新:
试验速览
- 阶段
- 不适用
- 状态
- 尚未招募
- 入组人数
- 60
- 试验地点
- 1
- 主要终点
- Intubation within 48 hours of extubation.
研究概览
简要总结
This study is being done to timely detect extubation failure by comparing mainstream PetCO2 monitoring and standard practice during non invasive ventilation (NIV) after extubation and to correlate arterial blood gas (ABG) with ETCO2 and PaCO2 method.
研究设计
- 研究类型
- Observational
入排标准
- 年龄范围
- 18.00 Year(s) 至 90.00 Year(s)(—)
- 性别
- All
入选标准
- •Patients of either sex and who are 18 years of age and above.
- •Patients who are admitted in ICU.
- •Patients who are planned for Non Invasive Ventilation after extubation.
- •Patients who are at high risk of extubation failure.
排除标准
- •Contraindication for Non Invasive Ventilation therapy.
- •Tracheostomized patients.
- •DNI (do not intubate) orders.
- •Accidental or self extubation.
- •Patients in whom arterial blood samples cannot be collected.
结局指标
主要结局
Intubation within 48 hours of extubation.
时间窗: Intubation within 48 hours of extubation.
次要结局
- Correlation between ETCO2 and PaCO2.(Comparison of:)
研究者
Dr Shirin Parveen
Era’s Lucknow Medical College and Hospital
研究点 (1)
Loading locations...
相似试验
招募中
不适用
Investigation Into the Dynamic Variations of End-Tidal Carbon Monoxide Concentration (ETCOc) in Neonates Utilizing Non-Dispersive Infrared Spectroscopy and Its Implications for Jaundice ManagementNeonatal HyperbilirubinemiaNCT07346976The Fourth Affiliated Hospital of Zhejiang University School of Medicine100
尚未招募
不适用
Role of End-Tidal CO2 During Passive Leg Raising to Predict Fluid Responsiveness in ICUNCT07304648Izmir Katip Celebi University68
Enrolling By Invitation
不适用
Test-Retest Reliability And Validation For End-Tidal Carbon Dioxide Measurement (PetCO2) During Rest And Low-Loaded Steady State Work Using A Portable Capnograph.NCT07326449Linkoeping University20
已完成
不适用
Comparison of End-tidal Carbon Dioxide (ETCO2) Measured by Transportable Capnometer (EMMATM) and the Arterial pCO2 in General AnesthesiaEnd Tidal Carbon Dioxide of Patients Undergoing General AnesthesiaNCT02184728Inje University35
尚未招募
不适用
Measurement of end tidal CO2(EtCO2) concentration during high frequency oscillatory ventilation in newbornsRespiratory fairure of naonatesJPRN-UMIN000040566agoya University Hospital60