跳至主要内容
临床试验/NCT01528150
NCT01528150已完成不适用

Clinical Investigation to Assess the Safety and Efficacy of the Tendril MRI™ Leads, as a Part of the Accent MRI™ System, in Patients With Standard Bradycardia Pacing Indication.

Abbott Medical Devices0 个研究点目标入组 466 人开始时间: 2012年2月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
466
主要终点
Freedom From RA and RV Lead-related Complications

研究概览

简要总结

The purpose of this observational study is the assessment (safety and efficacy) of the St. Jude Medical Tendril MRI™ leads. The Tendril MRI™ leads are a full part of the Accent MRI™ System, consisting of Tendril MRI™ leads and Accent MRI™ pacemaker. The subject population includes patients with a standard bradycardia pacing indication.

详细描述

Magnetic resonance imaging (MRI) is a diagnostic method to view high quality two and three dimensional images of the body. However, magnetic resonance imaging systems generate three electromagnetic fields that are used to produce an image. These include a static magnetic field, a time varying gradient magnetic field, and a radiofrequency field. All three of these fields interact with implanted devices and could create hazards for the device, the patient, or both. Due to these issues, currently marketed pacemaker systems may be contraindicated for use in an MRI environment.

St. Jude Medical has developed a system, the Accent MRI™ system, comprised of the Accent MRI™ device and the Tendril MRI™ lead, and an investigational MRI Activator™, designed to mitigate such interactions.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Approved Class I or Class II indication per: European Society of Cardiology (ESC) guidelines for implantation of a dual chamber pacemaker or single chamber pacemaker, OR American College of Cardiology (ACC) / American Heart Association (AHA) / Heart Rhythm Society (HRS) guidelines for implantation of a dual chamber pacemaker or single chamber pacemaker
  • Require a new Accent MRI™ pacemaker and Tendril MRI™ lead (either initial implant or complete system change out with no abandoned devices).
  • Is ≥ 18 years of age.
  • Able to provide written informed consent prior to any investigational related procedure.
  • Willing and able to comply with the prescribed follow-up tests and schedule of evaluations.

排除标准

  • Have an existing pacemaker or ICD (abandoned devices and/or leads are not allowed. A new pacemaker and lead or complete system change out is required for enrollment).
  • Have an existing active implanted medical device (e.g., Implantable Cardioverter Defibrillator (ICD), neurostimulator, etc.).
  • Have a non-MRI compatible device or material implant (e.g., intracranial aneurysm clip, non-MRI compatible devices or material, metals or alloys, etc.).
  • Have a lead extender, plug or adaptor.
  • Have a prosthetic tricuspid heart valve.
  • Are currently participating in another investigational device or drug investigation.
  • Are allergic to Dexamethasone sodium phosphate (DSP).
  • Are pregnant or planning to become pregnant during the duration of the study.
  • Have a life expectancy of less than 12 months from Screening due to any life-threatening condition

结局指标

主要结局

Freedom From RA and RV Lead-related Complications

时间窗: up to 12 months post-implant

Safety of the Accent MRI™ system with the Tendril MRI™ lead will be evaluated in terms of freedom from Right Atrial (RA) and Right Ventricular (RV) lead-related complications for the acute (implant to 2 month visit) and chronic (2 month visit through the 12 month visit) timeframes.

次要结局

未报告次要终点