跳至主要内容
临床试验/NCT03987321
NCT03987321Unknown不适用

Retrievability and Incidence of Complex Retrieval in Celect Versus Denali Filter: A Prospective, Randomized, Comparative Study

Yonsei University1 个研究点 分布在 1 个国家目标入组 174 人开始时间: 2019年7月最近更新:
适应症
干预措施

试验速览

阶段
不适用
入组人数
174
试验地点
1
主要终点
Incidence of complicated filter retrieval

研究概览

简要总结

The primary purpose of this study is to compare the Celect and Denali filters in terms of complicated filter retrieval and indwelling complications after a 2-month indwelling time.

详细描述

With anticoagulation being the standard treatment for deep venous thrombosis and pulmonary embolism, inferior vena cava filter placement plays an important role in patients who are amenable to anticoagulant therapy. Currently, many different types of retrievable filters are being used in clinical practice and the choice of the filters depends on operators' preference and institutional availability. Each filter has different designs to maximize retrievability and minimize indwelling complications. Up until now, the prior studies on the filter retrievability and indwelling complications have been retrospective in nature and had relatively long dwell times. Comparative data regarding the retrievability of the inferior vena cava filters may help to choose filter selection. Therefore, the aim of this trial is to compare two commonly used inferior vena cava filters (Denali and Celet filters)

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Single (Participant)

盲法说明

Participants are blinded to the filter type.

入排标准

年龄范围
18 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients who develop deep venous thrombosis and/or pulmonary embolism but are good candidates for anticoagulant therapy
  • Inferior vena cava filtration before mechanical thrombectomy for deep venous thrombosis
  • Prophylactic filter placement because of trauma or major surgery

排除标准

  • Those who need permanent filter placement
  • Congenital anatomical anomaly (IVC duplication, interrupted IVC)
  • patients who need filter placement in the suprarenal inferior vena cava

研究组 & 干预措施

Denali Group

Experimental

Those who received Denali filter placement

干预措施: Infrarenal vena cava filter placement (Device)

Celect Group

Experimental

Those who received Celect filter placement

干预措施: Infrarenal vena cava filter placement (Device)

结局指标

主要结局

Incidence of complicated filter retrieval

时间窗: 2 months after filter placement

Incidence of retrieval cases that require the use of standard retrieval kit (sheath and snare)

次要结局

  • Incidence of penetration(2 months after filter placement)
  • Filter migration(2 months after filter placement)
  • tilt angle(2 months after filter placement)
  • fracture(2 months after filter placement)
  • signs of inferior vena cava occlusion/stenosis(2 months after filter placement)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验