Balloon Expandable vs. Self Expanding Transcatheter Valve for Degenerated Bioprosthesis. THE BASELINE TRIAL.

Erasmus Medical Center16 个研究点 分布在 12 个国家目标入组 400 人开始时间: 2021年5月1日最近更新:
适应症

试验速览

阶段
不适用
状态
招募中
入组人数
400
试验地点
16
主要终点
Device success

研究概览

简要总结

Transcatheter aortic valve implantation (TAVI) serves a growing spectrum of patients with symptomatic severe aortic stenosis (AS). Approximately 80% of surgical aortic valve replacements is performed using a bioprosthesis1. Durability of surgical bioprostheses varies based on the patient's age at the moment of implantation, type and size etc2. TAVI has become the preferred treatment for degenerated aortic bioprostheses in elderly patients3. The median time since index surgical aortic valve replacement (SAVR) and for bioprosthetic valve degeneration is typically 8 - 10 years4-6. TAVI in this setting has proven to have equally favorable results as in native aortic valves7. Balloon expandable8 and self-expanding9 transcatheter heart valves (THV) can be used in a degenerated bioprosthesis and each have specific assets and limitations. TAVI in a failed bioprosthesis can cause coronary obstruction, THV migration, paravalvular leakage and prosthesis patient mismatch. The SAPIEN-3 / Ultra and EVOLUT R/Pro are the 2 most commonly used THV platforms in contemporary clinical practice including treatment of failing surgical aortic bioprostheses.

Objective: To compare TAVI with EVOLUT R/Pro vs. SAPIEN-3 / Ultra in terms of device success.

Study design: International multi-center randomized study with 1:1 randomization to TAVI with SAPIEN-3 / Ultra or Evolut R/Pro.

Study population: 440 patients with a failing surgical aortic bioprosthesis (aortic stenosis with or without aortic regurgitation) and selected for transfemoral TAVI by heart-team consensus.

Investigational intervention: Transfemoral TAVI with SAPIEN-3 / Ultra or Evolut R/PRO

Main study parameters/endpoints:

  1. Primary endpoint is device success at 30 days

Defined by

  • Absence of procedural mortality AND
  • Correct positioning of a single prosthetic heart valve into the proper anatomical location AND
  • Intended performance of the prosthetic heart valve (no severe prosthesis- patient mismatch and mean aortic valve gradient < 20 mmHg or peak velocity < 3 m/s, AND no moderate or severe prosthetic valve regurgitation). Severe prosthesis patient mismatch is defined by effective orifice area (EOAi) ≤0.65 cm2/m2
  1. Safety endpoint at 1 year defined by the composite of all-cause death, disabling stroke, rehospitalization for heart failure or valve related problems.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
65 Years 至 —(Older Adult)
性别
All
接受健康志愿者

入选标准

  • Age ≥ 65 years
  • Failing surgical aortic bioprosthesis requiring valve replacement and eligible for transfemoral TAVI with balloon expandable or self-expanding platform per heart team consensus based on multi-modality imaging assessment (including echocardiography and multidetector CT).
  • Written informed consent

排除标准

  • Not eligible for Transfemoral TAVI with SAPIEN-3 / Ultra and Evolut R/Pro
  • Multi-valve defects requiring intervention
  • Clinically unstable and/or inotropic/vasopressor /mechanical support.
  • Known mural thrombus in the left ventricle
  • Presence of a mechanical aortic valve
  • History of recent (within 1 month) stroke or TIA

结局指标

主要结局

Device success

时间窗: 30 days post transcatheter valve implantation

Device success, definition modified from VARC-2 criteria: * Absence of procedural mortality AND * Correct positioning of a single prosthetic heart valve into the proper anatomical location AND * Intended performance of the prosthetic heart valve (no severe prosthesis- patient mismatch and mean aortic valve gradient \< 20 mmHg or peak velocity \< 3 m/s, AND no moderate or severe prosthetic valve regurgitation). Severe prosthesis patient mismatch is defined by effective orifice area (EOAi) ≤0.65 cm2/m2

次要结局

  • Composite of all-cause death, disabling stroke, rehospitalization for heart failure or valve related problems(1 year post transcatheter valve implantation)