跳至主要内容
临床试验/NCT07614100
NCT07614100尚未招募不适用

Cerebral Microembolization During Transcatheter Aortic Valve Implantation: A Randomized Study Comparing Balloon-expandable and Self-expanding Valves

Ivan Zeljkovic2 个研究点 分布在 1 个国家目标入组 80 人开始时间: 2026年6月1日最近更新:
适应症

试验速览

阶段
不适用
状态
尚未招募
发起方
入组人数
80
试验地点
2

研究概览

简要总结

This study will compare the amount of cerebral microembolization during transcatheter aortic valve implantation (TAVI) between two commonly used types of transcatheter aortic valves: balloon-expandable valves and self-expanding valves.

Cerebral microembolization refers to small particles or material that may travel to the brain during the procedure. These signals can be detected using transcranial Doppler ultrasound, a non-invasive method for monitoring blood flow in the brain. Although clinically apparent stroke after TAVI is relatively uncommon, small silent brain lesions may occur, and their mechanisms are not fully understood.

Adult patients with severe symptomatic aortic valve stenosis who are scheduled for TAVI will be included. Participants will be randomly assigned to receive either a balloon-expandable or a self-expanding valve, both of which are established and routinely used treatment options. Transcranial Doppler monitoring will be performed before, during, and after the procedure to record the number of microembolic signals. The study will also record neurological events and procedural characteristics, such as procedure duration and the need for balloon dilatation.

The aim of the study is to determine whether the type of valve is associated with a different burden of cerebral microembolization during TAVI. The results may help improve understanding of procedural factors related to cerebral embolization and may support future strategies for reducing neurological risk in patients undergoing TAVI.

详细描述

This is a prospective, randomized, parallel-group clinical study designed to compare cerebral microembolization during transcatheter aortic valve implantation between balloon-expandable and self-expanding transcatheter aortic valves.

The study will be conducted at University Hospital Dubrava and Sisters of Charity Hospital (Zagreb) with an expected duration of one year. Adult patients aged 18 years or older with severe symptomatic aortic valve stenosis and an indication for transcatheter aortic valve implantation will be considered for participation.

Eligible participants will be randomized using a computer-generated randomization sequence into one of two study groups according to the type of implanted valve: a balloon-expandable valve or a self-expanding valve. Both valve types represent standard, widely accepted therapeutic options in contemporary clinical practice. The study does not introduce a new or insufficiently tested technology, and participation will not change the standard course of treatment or expose patients to additional risk beyond that normally associated with the procedure.

All participants will undergo a standard TAVI procedure with periprocedural anticoagulation according to current clinical guidelines. Cerebral microembolization will be assessed using transcranial Doppler ultrasound. Monitoring will be performed immediately before the procedure, during the procedure, and after the procedure. The presence and number of microembolic signals will be recorded, including analysis across specific procedural phases such as instrumentation, valvuloplasty, valve implantation, and the post-implantation period.

The primary outcome will be the difference in the change in the number of microembolic signals between the balloon-expandable and self-expanding valve groups. Secondary outcomes will include the change in microembolic signal burden within each group, the distribution of microembolic signals across procedural phases, the occurrence of new microembolic signals after the procedure, the incidence of clinical neurological events, and the association between procedural characteristics and microembolic signal burden.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Age 18 years or older
  • Severe symptomatic aortic valve stenosis
  • Clinical indication for transcatheter aortic valve implantation
  • Feasibility of transcranial Doppler ultrasound monitoring
  • Signed written informed consent

排除标准

  • Recent stroke or transient ischemic attack
  • Significant cerebrovascular disease preventing reliable transcranial Doppler -assessment
  • Previous aortic valve implantation
  • Active endocarditis
  • Pregnancy or breastfeeding

研究者

发起方
Ivan Zeljkovic
申办方类型
Other
责任方
Sponsor Investigator
主要研究者

Ivan Zeljkovic

Principal Investigator and Head of Diagnostic and Therapeutic Department for Cardiac Electrostimulation and Electrophysiology

University Hospital Dubrava

研究点 (2)

Loading locations...

相似试验

Cerebral Microembolization During Transcatheter... | 临床试验