Optimized Programming in a Multiple-Independent Current Sources Spinal Cord Stimulation (SCS) System

Boston Scientific Corporation2 个研究点 分布在 1 个国家目标入组 20 人开始时间: 2009年3月最近更新:
适应症

试验速览

阶段
4 期
状态
已完成
入组人数
20
试验地点
2
主要终点
Correlation Coefficient Between Dorsal Root Paresthesia (Total Pixels Derived From Digital Drawing) at Maximum-comfortable Stimulation Level and Anode-cathode Separation Distance (mm)

研究概览

简要总结

The objective of this study is to evaluate extent, location, and perception of paresthesia as a function of anode/cathode configuration.

详细描述

The clinical results from this study may help to validate predictions made by mathematical models of neurons that are activated by SCS and increase scientific knowledge about the way in which different programs relate to satisfactory outcomes, such that use of the model may help in the development of new products.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Supportive Care
盲法
Double (Participant, Investigator)

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Be previously implanted with Precision SCS System (3-36 months post permanent implant) having 2 parallel percutaneous leads placed between T8-T
  • Be implanted with Precision SCS System for the treatment of neuropathic pain of trunk and/or limbs
  • Be 18 years of age or older
  • Be extremely satisfied, very satisfied, or satisfied with SCS therapy for treatment of pain condition
  • Be able to use pen tablet to document regions of paresthesia and pain
  • Be able to lie in the supine position for 45 minutes at a minimum
  • Be able to verbally report qualitative and quantitative aspects of paresthesia sensations.
  • Have a paresthesia threshold on a standard program below 4mA while in the supine position
  • Have at minimum the upper contact of one lead below T8 and the lower contact above T11 vertebral levels
  • Be willing and able to comply with study-related procedure
  • Agree to study requirements and provides written Informed Consent

排除标准

  • Unable to read, write, speak, and understand English
  • Currently pregnant or planning to become pregnant during the course of the study
  • Have negative finding in any of the pre-screening and screening requirements
  • Upon fluoroscopy, location of both leads is identified to be outside T8-T10 vertebral levels
  • Unable to perceive the sensation of paresthesia associated with stimulation in the trunk and/or lower extremities
  • Have a drug pump and/or a non-Precision neurostimulation device (regardless of whether active or inactive)
  • Have had any interventional pain procedure or surgeries (including Interlaminar epidural steroid injection, Transforaminal epidural steroid injection, Caudal epidural steroid injection, Selective nerve root block, Intraarticular lumbar facet injection, Sacroiliac joint injection, Piriformis muscle injection, Trochanteric bursa injection, Hip/knee joint injections, Medial branch block (innervates facet joint), Pulsed radiofrequency neurotomy medial branches, Pulsed radiofrequency dorsal root ganglion, Thermal (high temperature) radiofrequency neurotomy medial branches, Trigger point injections, and Botulinum toxin injections) involving the spine within the past 30 days
  • Have any condition that is likely to confound evaluation of study endpoints. Conditions that may make paresthesia coverage variable over the course of the study include multiple sclerosis, partial spinal cord injury, diabetic peripheral neuropathy, peripheral vascular disease, scoliosis, deafferentation, etc.

结局指标

主要结局

Correlation Coefficient Between Dorsal Root Paresthesia (Total Pixels Derived From Digital Drawing) at Maximum-comfortable Stimulation Level and Anode-cathode Separation Distance (mm)

时间窗: Immediately post-procedure

次要结局

未报告次要终点