跳至主要内容
临床试验/NCT01734980
NCT01734980已完成不适用

Comparison Of Cytologic Accuracy Of Endobronchial Ultrasound Transbronchial Needle Aspiration Using Needle Suction Versus No Suction

Northwell Health1 个研究点 分布在 1 个国家目标入组 30 人开始时间: 2011年2月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
30
试验地点
1
主要终点
Diagnostic yield

研究概览

简要总结

Cytological diagnostic accuracy between endobronchial ultrasonography endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) samples using suction versus samples when no suction is applied.

详细描述

Endobronchial ultrasound-guided transbronchial needle aspiration which is known as the EBUS procedure is a low risk procedure performed using bronchoscopy to sample chest lesions. A needle is passed through the bronchoscope to biopsy the chest lesion. Every lesion is usually biopsied 3 to 7 times. In most cases the investigators apply a syringe with negative pressure to the needle inserted into lesion for biopsy. In some cases the investigators don't apply any negative pressure. There are no studies to evaluate which one is better, applying syringe suction or no suction.

In our study, the investigators are planning to do biopsies with or without suction. Then, the pathology samples will be evaluated for any cytologic difference in making the diagnosis. Any patient undergoing the EBUS procedure for chest biopsies will be eligible. Every lesion will be biopsied at least twice with needle with and without suction. The biopsy samples will be then divided into group A where the investigators applied syringe suction and group B where no syringe suction was applied. There is no risk to the patient in addition to the risk of the EBUS procedure itself. The investigators are not performing any additional intervention from the usual standard of care for any patient presenting for the EBUS procedure. Essentially the investigators are simply grouping the suction and no suction pathology samples as A and B for pathologic comparison.

RESULTS: Among the 26 participants, one of the patients (3.8%) had no adequate tissue using both methods; one patient (3.8%) had adequate tissue using suction but no adequate tissue using no suction; and 24 patients had adequate tissue using both methods (92.3%, p= 1.00). Among the twenty-four patients with adequate tissue using both methods, 14 patients (58.3%) had benign pathology using both methods, while ten patients (41.7%) had malignant pathology using both methods (p= 1.00). Considering suction to be the golden method, the sensitivity and specificity of no suction were 100%. Among the 32 sites that were sampled, one site (3.1%) had no adequate tissue using both methods; one site (3.1%) had adequate tissue using suction but no adequate tissue using no suction; and 30 sites had adequate tissue using both methods (93.8%, p= 1.00). Among the thirty sites with adequate tissue using both methods, 17 (56.7%) had benign pathology using both methods; 12 (40.0%) had malignant pathology using both methods; and one site (3.3%) had malignant pathology using suction, but benign pathology using no suction (p= 1.00). Considering suction to be the golden method, the no suction had a sensitivity= 92.3% and specificity= 100%.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •All adult subjects who are scheduled to undergo endobronchial ultrasound transbronchial aspiration to sample mediastinal masses or lymph nodes.

排除标准

  • •Patients who are not able to complete the EBUS procedure for any reason

研究组 & 干预措施

Endobronchial Ultrasound

Experimental

EBUS-TBNA is a procedure that allows accurate sampling of mediastinal lymph nodes and peribronchial lesions

干预措施: Endobronchial Ultrasound (Procedure)

结局指标

主要结局

Diagnostic yield

时间窗: 3 days

The number of patients with cytological diagnosis as a measure of effective diagnostic technique.

次要结局

  • Samples adequacy(3 days)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Michel Chalhoub

Principal Investigator

Northwell Health

研究点 (1)

Loading locations...

相似试验