Effectiveness and Safety Study of the Percutaneous Optical Fibre Glucose Sensor (FiberSense) for Home Use in Diabetic and Prediabetic Individuals

Lee's Pharmaceutical Limited1 个研究点 分布在 1 个国家目标入组 26 人开始时间: 2017年11月14日最近更新:
适应症
干预措施

试验速览

阶段
不适用
发起方
入组人数
26
试验地点
1
主要终点
Blood glucose

研究概览

简要总结

This study evaluates the performance and safety of the fluorescence based fibre optic glucose sensor for home usage.24 subjects will take part in the study, including 4 pre-diabetic subjects, 8 Type I diabetic patients, 8 Type II diabetic patients and 4 diabetic patients who require continuous ambulatory peritoneal dialysis (CAPD). Type 1, Type 2 and prediabetic subjects will wear one FiberSense sensor, randomly allocated to either the upper arm (50%) or abdomen (50%) for 28 days. In addition, these subjects will wear a Dexcom sensor on the other side of the abdomen for 7 days in one of the four study weeks. In all 4 CAPD subjects, one FiberSense sensor will be placed in the upper arm for 28 days. No additional comparator sensor will be placed in CAPD subjects.

详细描述

The FiberSense system is a glucose-monitoring device indicated for continually recording interstitial fluid glucose levels in patients ages 18 and older with insulin dependent diabetes mellitus for the purpose of improving diabetes management. The System is intended for use by patients at home and in health care facilities.

The FiberSense system is indicated for use as an adjunctive device to complement, not replace, information obtained from standard home glucose monitoring devices.

The FiberSense system aids in the detection of episodes of hyperglycemia and hypoglycemia, facilitating both acute and long-term therapy adjustments, which may minimize these excursions.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 70 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Type I or II diabetes mellitus requiring insulin in the management of glucose control for at least one year prior to enrollment or diabetes on continuous ambulatory peritoneal dialysis or prediabetic individuals with impaired fasting glucose or impaired glucose tolerance by OGTT
  • Male or female age ≥ 18 years old and ≤ 70 year old.
  • Women who are not pregnant, lactating or planning a pregnancy during their participation in the clinical study.
  • Willingness, ability and commitment to comply with the testing, procedure and follow-up outlined in this protocol including (but not limited to) frequency of clinic visits and use of pre-specified glucose monitoring devices.
  • Willingness to abstain from swimming during their participation in the measurement phase.
  • In the opinion of the investigator, absence of any physical limitations, addictive diseases, or underlying medical conditions (including mental health) that may preclude the patient from being a good study candidate.
  • Written informed consent to participate in the study provided by the patient.

排除标准

  • Poorly controlled diabetes mellitus with HbA1C >11%.
  • Currently pregnant, as demonstrated by a positive pregnancy test at screening and on Day00 .
  • Impaired hepatic function measured as alanine aminotransferase (ALT) or aspartate aminotransferase (AST) ≥ three times the upper reference limit.
  • Any active acute or chronic disease or condition that, in the opinion of the investigator, might interfere with the performance of this study.
  • Any active acute or chronic infectious disease that, in the opinion of the investigator, would pose an excessive risk to study staff.
  • Current use or recent exposure to any medication that in the opinion of the investigator could have an influence on the patient's ability to participate in this study or on the performance of the test device.
  • Extensive skin changes/diseases that preclude wearing the required number of devices on normal skin at the proposed application sites (e.g., extensive psoriasis, recent burns or severe sunburn, extensive eczema, extensive scarring, extensive tattoos, dermatitis herpetiformis).
  • Have a known allergy to medical-grade adhesives, or known hypersensitivity to any of the products used in the study.
  • Known current or recent alcohol or drug abuse
  • Blood donation of more than 500 ml within the last three months
  • Currently participating in another investigational study protocol where the testing or results may interfere with study compliance, diagnostic results, or data collection.
  • Has a MRI scan, CT scan, or diathermy scheduled during the proposed study participation.
  • An identified protected vulnerable patient (including but not limited to those in detention, or a prisoner).
  • Women of reproductive potential who are unwilling to adopt contraceptive measures during the study period

研究组 & 干预措施

FiberSense sensor

Experimental

Type 1, Type 2 and prediabetic subjects will wear one FiberSense sensor, randomly allocated to either the upper arm (50%) or abdomen (50%) for 28 days. In addition, these subjects will wear a Dexcom sensor on the other side of the abdomen for 7 days in one of the four study weeks.

In all 4 CAPD subjects, one FiberSense sensor will be placed in the upper arm for 28 days. No additional comparator sensor will be placed in CAPD subject.

干预措施: FiberSense sensor (Device)

FiberSense sensor

Experimental

Type 1, Type 2 and prediabetic subjects will wear one FiberSense sensor, randomly allocated to either the upper arm (50%) or abdomen (50%) for 28 days. In addition, these subjects will wear a Dexcom sensor on the other side of the abdomen for 7 days in one of the four study weeks.

In all 4 CAPD subjects, one FiberSense sensor will be placed in the upper arm for 28 days. No additional comparator sensor will be placed in CAPD subject.

干预措施: Dexcom Sensor (Device)

结局指标

主要结局

Blood glucose

时间窗: 28 days

The primary endpoint is the proportion of FiberSense readings within ≤15% of the reference (YSI) reading for blood glucose levels \>100 mg/dl, and the proportion of FiberSense readings within ≤15 mg/dl of the YSI reading for blood glucose levels ≤100 mg/dl, for paired samples taken during the in-clinic sessions.

Adverse Events reporting

时间窗: 35 days

次要结局

  • Accuracy of glucose rate of change of FiberSense sensor compared to glucose rate of change of YSI(28 days)
  • Hyperglycemia detection rates(28 days)
  • Median Relatives Differences from YSI(28 days)
  • Median Absolute Relative Differences from YSI(28 days)
  • Hypoglycemia detection rates(28 days)
  • Mean Relatives Differences from YSI(28 days)
  • Mean Absolute Relative Differences from YSI(28 days)
  • Lag time between FiberSense readings and YSI results during induced glucose excursions(28 days)
  • User satisfaction questionnaire score(28 days)
  • Agreement and accuracy relative to SMBG readings (same model to be used by all subjects)(28 days)
  • Calibration stability(28 days)
  • Sensor stability(28 days)
  • Sensor life(28 days)
  • Blood maltose concentrations(28 days)