跳至主要内容
临床试验/NCT07645079
NCT07645079尚未招募不适用

Inpatient Diabetes Management With Automated Insulin Delivery Systems Compared to Multiple Daily Injections With a Basal-bolus Regimen - a Randomized Controlled Trial

Steno Diabetes Center Copenhagen2 个研究点 分布在 2 个国家目标入组 92 人开始时间: 2026年7月1日最近更新:
适应症

试验速览

阶段
不适用
状态
尚未招募
入组人数
92
试验地点
2

研究概览

简要总结

Aim

The investigators aim to investigate if automated insulin delivery systems (AID) improve in-hospital glycemic and clinical outcomes in patients with type 2 diabetes compared to standard-of-care with a pen-basal-bolus insulin regimen manually titrated by general staff at Herlev-Gentofte Hospital and a clinical decision support system (GlucoTab) titrating the basal-bolus regimen automatically daily at Graz University Hospital.

Population

Hospitalized patients with type 2 diabetes in non-intensive care units (non-ICU) at medical wards at Copenhagen University Hospitals of Herley-Gentofte (affiliated with Steno Diabetes Center Copenhagen) and Medical University Hospital of Graz (N = 92).

Design

This is an investigator-initiated, two-armed, two-site, prospective, randomized, open-label, blinded endpoint (PROBE) trial.

Objectives

The objective is to determine the glycemic and clinical effects of inpatient AID systems in non-ICU patients with type 2 diabetes. Participants will be randomized in a usual-of-care and an AID arm. Diabetes management will be performed by usual care in the control arm based on a basal-bolus insulin regimen and point-of-care (POC) glucose testing. A continuous glucose monitoring (CGM) system (Abbott FreeStyle Libre 3) will be used in all groups for outcome analysis and comparison between the groups. The CGM will be blinded for the control arm, to not interfere with the usual of care because of the higher amount of glucose data. The AID-arm will be managed by an AID system with real-time CGM data transmitted to nursing stations.

Outcomes

Primary outcome: The primary outcome is the difference in CGM-recorded time in range (TIR) (70-180 mg/dl (3.9-10.0 mmol/l)) between the POC- and the CGM-arm according to the 2023 in-hospital CGM consensus during the entire hospital stay.

Secondary outcomes: Outcomes are reported according to the 2023 in-hospital CGM consensus and specified in the protocol during the entire hospital stay, including three levels of time above range (TAR) 180-250mg/dl (10.0-13.9 mmol/l), >250mg/dl (>13.9 mmol/l), and >180mg/dl (>10.0 mmol/l); three levels of time below range (TBR) 54-70mg/dl (3.0-3.9 mmol/l), <54mg/dl (<3.0 mmol/l), and <70mg/dl (<3.9 mmol/l); events of hypoglycemia in three levels, 54-68mg/dl (3.0-3.8 mmol/l), <54mg/dl (< 3.0 mmol/l), and <70mg/dl (<3.9 mmol/l), where the glucose values between the two hypoglycemic events must all be >70mg/dl (>3.9 mmol/l) for at least 15 consecutive minutes(1), including prolonged hypoglycemic events (> 120 minutes), recurrent hypoglycemic events (events preceded by another hypoglycemic event), and recurrent hypoglycemic days (percentage of days with at least one hypoglycemic event on separate days that is preceded by another in-hospital day with hypoglycemia(1)); mean glucose level; standard deviation (SD) of the CGM glucose distribution; coefficient of variation (CV); and insulin doses during hospitalization.

Clinical outcomes: The investigator assess the length of hospital stay as calculated from time of admission until discharge; in-hospital mortality; admissions to intensive care unit; any in-hospital-related complications occurring at least one day after randomization and until discharge, as documented and defined by the treating physician in the electronic health record (e.g., acute kidney injurie, sepsis, etc.)

Method

For the usual-of-care-arm, glucose assessment is done by standard POC glucose testing and insulin is manually titrated by general staff at Herlev-Gentofte Hospital and the glucose assessment is done by standard POC glucose testing and insulin is manually titrated by the GlucoTab system titrating the basal-bolus regimen automatically daily at Graz University Hospital. For the AID-arm, CGM data informs in real time the mylife Ypsopump for automated insulin delivery.

Device

The investigational device is the AID system, containing of the mylife YpsoPump and the FreeStyle Libre 3 sensor.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Treatment
盲法
Double (Participant, Care Provider)

盲法说明

The CGM-arm will be masked, the AID-arm will be open-label.

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • A documented history of Type 2 diabetes mellitus (T2DM) which requires subcutaneous insulin therapy
  • acute infectious disease of any kind
  • age ≥ 18 years old
  • willingness and ability to comply with theclinical investigation plan
  • ability to communicate with the trial personal
  • an expected length of hospital stay for at least 2 days after enrolment

排除标准

  • Patients already using AID for their glycemic management
  • Patients in use of an insulin pump
  • Skin pathologies that hinder application of a FreeStyle Libre-3 CGM and mylife YpsoPump
  • Participation in another trial, which could influence the outcome of the trial
  • Any mental condition rendering the patient incapable of giving informed consent
  • Known or suspected allergy to adhesive material/tape of the Libre-3-sensor and/or YpsoPump
  • Any disease or condition which the investigator or treating physician feels would interfere with the trial or the safety of the patient
  • Diagnoses/treatments/clinical parameters prohibiting use of Insulin/AID such as
  • Estimated glomerular filtration rate (eGFR) <15 mL/min/1.73 m2 OR
  • Treated with hydroxyurea/hydroxycarbamide OR
  • Nutritional therapy (continuous enteral or parenteral feeding) OR
  • Clinically relevant pancreatic disease OR
  • Aystemic glucocorticoid treatment with prednisone equivalent dose >5 mg/day OR
  • Expected to require admission to the intensive-care unit OR > Patients in dialysis

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验