Pulse Oximeter Accuracy During Stable Hypoxia Plateaus

Nihon Kohden1 个研究点 分布在 1 个国家目标入组 48 人开始时间: 2025年12月3日最近更新:
干预措施

试验速览

阶段
不适用
状态
进行中(未招募)
发起方
Nihon Kohden
入组人数
48
试验地点
1
主要终点
Accuracy of Sensor Oxygen Saturation by Arms Calculation

研究概览

简要总结

The aim of this study is to determine the accuracy of devices called pulse oximeters, which measure blood oxygen by shining light through fingers, ears or other skin, without requiring blood sampling. Study will be used with healthy volunteers at rest.

详细描述

This study will evaluate the accuracy of Nihon Kohden pulse oximeters and sensors in measuring arterial oxygen saturation (SpO₂) in healthy adult volunteers. Subjects will undergo controlled reductions in blood oxygen levels (down to 70%) while SpO₂ readings from the test devices are compared to reference values from arterial blood samples. The study is designed to meet current ISO and FDA requirements, and results may be used to support regulatory submissions. Data will be analyzed for overall accuracy and potential differences by skin tone and sex.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Prospective

入排标准

年龄范围
18 Years 至 50 Years(Adult)
性别
All
接受健康志愿者

入选标准

  • The subject is male or female, aged 18 to
  • The subject is in good general health with no evidence of any medical problems
  • The subject is fluent in both written and spoken English.
  • The subject has provided informed consent and is willing to comply with the study procedures.

排除标准

  • The subject has a BMI above 40
  • The subject has blood pressure above 160 systolic or 95 diastolic
  • The subject has a known history of heart disease, lung disease, kidney or liver disease.
  • Diagnosis of asthma, sleep apnea, or use of CPAP.
  • Subject has diabetes.
  • Subject has a clotting disorder.
  • The subject has a hemoglobinopathy or history of anemia, per subject report or the first blood sample, that in the opinion of the investigator, would make them unsuitable for study participation. (COHb<3%, MetHb<2%, ctHb>10 g/dL).
  • The subject has any other serious systemic illness.
  • The subject has smoked in the last 12 hours.
  • Any injury, deformity, or abnormality at the sensor sites that in the opinion of the investigators would interfere with the sensors working correctly.
  • The subject has a history of fainting or vasovagal response.
  • The subject has a history of sensitivity to local anesthesia.
  • The subject has a diagnosis of Raynaud's disease.
  • The subject has unacceptable collateral circulation based on exam by the investigator (Allen's test).
  • The subject is pregnant, lactating or trying to get pregnant.
  • Subjects who have uneven skin tones at the forehead or the sensor site.
  • The subject is unable or unwilling to provide informed consent or is unable or unwilling to comply with study procedures.
  • The subject has any other condition, which in the opinion of the investigators would make them unsuitable for the study.

研究组 & 干预措施

Adult healthy subjects

Adult healthy subjects capable of undergoing controlled hypoxemia to the levels outlined in the desaturation profile in an at rest state

干预措施: Pulse Oximeter (Device)

Adult healthy subjects

Adult healthy subjects capable of undergoing controlled hypoxemia to the levels outlined in the desaturation profile in an at rest state

干预措施: Induced hypoxia through breathing nitrogen-air-carbon dioxide mixture (Procedure)

结局指标

主要结局

Accuracy of Sensor Oxygen Saturation by Arms Calculation

时间窗: Up to 15 min

Accuracy will be determined by comparing the noninvasive blood oxygen saturation measurement of the pulse oximeter (SpO2) to that obtained from a blood sample (SaO2) and calculating the arithmetic root mean square (Arms) error value as follows: Arms = Square root (sum of n samples of ((SpO2i - SRi) squared) / n)