ExoAtlet II Lower Extremity Exoskeleton Safety and Efficacy Use With Spinal Cord Injured Individuals
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 20
- 试验地点
- 2
- 主要终点
- Number of adverse events
研究概览
简要总结
This study will evaluate the ExoAtlet II exoskeleton for safety and effectiveness of providing persons with a spinal cord injury (SCI) who are non-ambulatory or have limited ambulatory function, to stand up and ambulate under a variety of conditions.
详细描述
The study will introduce the ExoAtlet II exoskeleton to SCI patients with lower extremity paralysis (partial or complete) and provide rehabilitative standing and walking intervention. The study will be conducted with a trained clinician that will fit each patient into the adjustable exoskeleton system and provide customized programming to meet each user's specific needs. The training program will be initiated based upon each patient's comfort in the exoskeleton and ability to stand with assistance. Each patient will be closely monitored to assess ongoing health as well as their individual standing and walking ability. All exoskeleton sessions will be performed with a trained medical professional controlling the exoskeleton. Patient safety is the primary concern and all adverse events will be documented and addressed. This study will evaluate the ExoAtlet 2.0 exoskeleton for safety and effectiveness of providing persons with a spinal cord injury (SCI) who are non-ambulatory or have limited ambulatory function, the ability to stand up and walk in a clinical facility.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 80 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •18 Years of age or older in general good health
- •Weight, no more than 220lbs (100kg)
- •Skin must be healthy where it touches the ExoAtlet 2.0
- •Able to stand using a device such as a standing frame
- •Have enough strength in your hands and shoulders to support yourself standing and walking using crutches or a walker
- •Have good control of upper body
- •Determined to have enough bone health to walk full weight bearing without risk of fracture. Meeting of this condition is at the discretion of your personal MD
- •Passive range of motion (PROM) at shoulders, trunk, upper extremities and lower extremities within functional limits for safe gait and use of appropriate assistive device/stability aid
- •Hip width no greater than 18" (46 cm) measured when sitting.
- •Femur length between 37 cm and 49 cm measured between mid patellar tendon and the floor.
- •In general, good health and able to tolerate moderate levels of activity.
- •Blood pressure and heart rate within established guidelines for locomotive training: At rest; Systolic 150 or less Diastolic 90 or less and Heart rate 100 or less Exercise; Systolic 180 or less, Diastolic 105 or less and Heart Rate 145 or less
排除标准
- •Spinal cord injury level higher than T4 or C7 ASIA D
- •Severe muscle stiffness/tightness
- •Significant spasticity (Modified Ashworth Scale score of 3 or above)
- •Trunk or lower extremity pressure ulcer
- •Open Wounds/tissue hypersensitivity
- •Unstable spine, un-healed limbs, or fractures
- •Severe sensitivity to touch
- •Presence of bone in soft tissue where bone normally does not exist (heterotopic ossification), limiting range of motion in the hip or knee joints
- •Joint instability, dislocation, moderate to severe hip dysplasia
- •Significant scoliosis (>40 degrees)
- •Hardware, implant, or any external device impeding with safe fitting or use of ExoAtlet 2.0
- •Femoral or tibial rotation deformity (>15 degrees)
- •Significant flexion contractures limited to 35º at the hip and 20º at the knee
- •Uncontrolled seizures, musculoskeletal injury, fracture or lower-limb surgery in past year.
- •Known history of pulmonary disease limiting exercise tolerance or history of cardiac disease
- •Psychopathology, or other condition that the physician or investigator, in his or her clinical judgment, considers to be exclusionary to safely use an exoskeleton.
- •Severe concurrent medical diseases, illness, systemic or peripheral infection
- •Dizziness or headache with standing
- •History of autonomic dysreflexia
- •Orthostatic Hypotension: Decrease in Systolic BP > 20, Diastolic BP > 10 upon standing from a seated position.
- •Pregnant or lactating females
结局指标
主要结局
Number of adverse events
时间窗: 0-8 weeks
Document and track any adverse events, both minor and major, during exoskeleton sessions.
Skin integrity
时间窗: 0-8 weeks
A visual inspection of the participant's skin, at all areas of contact with the exoskeleton, will be conducted at the beginning and end of each session.
次要结局
- 10 Meter Walk Test(1 Day)
- Transfer in and out(2 Days)
- 6 Minute Walk Test(1 Day)
- Perform Sit to Stand to Sit(2 Days)