Pivotal Study of the CADence Device in Detection of Coronary Artery Diseases

AUM Cardiovascular, Inc.24 个研究点 分布在 1 个国家目标入组 1,014 人开始时间: 2013年6月14日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
1,014
试验地点
24
主要终点
Sensitivity and Specificity of CADence to Detect Stenosis Relative to SPECT Performance, Using Either CT or Standard Angiogram as the Gold Standard

研究概览

简要总结

This is a multi-center, prospective, non-randomized, double-blinded trial to evaluate the sensitivity and specificity of the CADence device in detecting the existence of clinically significant coronary artery disease as determined by either standard or CT angiography.

详细描述

This is a multi-center, prospective, non-randomized, double-blinded, trial to evaluate the performance of the CADence in detecting the existence of at least one major coronary artery with clinically significant stenosis in a subject is defined as the presence of at least one lesion with ≥ 70% diameter stenosis anywhere in the proximal Left anterior Descending, mid Left anterior Descending, proximal Left Circumflex, mid Left Circumflex , proximal Right Coronary Artery, mid Right Coronary Artery, distal Right Coronary Artery and Obtuse Margin 1, Obtuse Margin 2, and Ramus Intermedius if segment diameter >2.5 mm or ≥50% diameter stenosis in the Left Main coronary arteries.

Consented subjects will be evaluated with the CADence device and then undergo nuclear stress testing followed by either computed tomography or standard coronary angiography. The maximum expected timeframe between CADence and computed tomography Angiography or standard angiography is 6 weeks.

This is a double-blinded study. All physicians and subjects will be masked to the diagnostic results of the CADence until completion of CADence, nuclear stress, computed tomography or standard coronary angiogram testing for the subjects. Patient care will not be based on the CADence results.

Study participation will conclude after the computed tomography angiography or standard coronary angiography procedure.

computed tomograph or standard coronary angiography are considered acceptable clinical reference standards in this study and are gold standards for detection of coronary artery disease. The experimental unit of this study is the subject. Existence of clinically significant coronary artery disease in a subject is defined as the presence of at least one lesion with ≥ 70% diameter stenosis anywhere in the proximal Left anterior Descending, mid Left anterior Descending, proximal Left Circumflex, mid Left Circumflex, proximal Right Coronary Artery, mid Right Coronary Artery, distal Right Coronary Artery and Obtuse Margin 1, Obtuse Margin 2, and Ramus Intermedius if segment diameter >2.5 mm or ≥50% diameter stenosis in the Left Main coronary arteries.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Prospective

入排标准

年龄范围
22 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • 未提供

排除标准

  • 未提供

结局指标

主要结局

Sensitivity and Specificity of CADence to Detect Stenosis Relative to SPECT Performance, Using Either CT or Standard Angiogram as the Gold Standard

时间窗: No more than 3 weeks between CADence, SPECT and standard or CT angiogram

The CADence will be considered to have demonstrated effectiveness in detecting the presence of at least one lesion with ≥ 70% diameter stenosis anywhere in the proximal Left anterior Descending (pLAD), mid Left anterior Descending (mLAD), proximal Left Circumflex (pLCx), mid Left Circumflex (mLCx), proximal Right Coronary Artery (pRCA), mid Right Coronary Artery (mRCA), distal Right Coronary Artery (dRCA) and Obtuse Margin 1 (OM1), Obtuse Margin 2 (OM2), and Ramus Intermedius (RI) if segment diameter \>2.5 mm or ≥50% diameter stenosis in the Left Main coronary arteries if sensitivity and specificity are non-inferior within 15 percentage points to a sensitivity of 83% and a specificity of 80%, which is the literature-based Objective Performance Criteria (OPC) for nuclear stress tests.