跳至主要内容
临床试验/NCT04789044
NCT04789044进行中(未招募)2 期

A Phase 2a Multicenter Randomized Controlled Trial Evaluating the Safety and Efficacy of Polyethylene Glycol (PEG) Mediated Fusion (PEG Fusion) Compared to Standard of Care in the Repair of Mixed Motor-sensory Acute Peripheral Nerve Injuries (PNI) for Rapid and Immediate Improvement in Outcome

Major Extremity Trauma Research Consortium14 个研究点 分布在 1 个国家目标入组 40 人开始时间: 2023年6月1日最近更新:
适应症
干预措施
相关药物

试验速览

阶段
2 期
状态
进行中(未招募)
发起方
入组人数
40
试验地点
14
主要终点
Complications or problems that occur with in the first 30 days.

研究概览

简要总结

The overall objective of this study is to determine the safety of PEG fusion when used with primary repair or reconstruction in patients with an acute upper extremity peripheral nerve injury. PEG is safe and effective for extending the half-life of circulating pharmaceutical products, when used in conjunction with a topical hemostatic agent in surgical wounds, and when used as a colon cleanser for endoscopic surgical procedures. However, PEG fusion has not been rigorously tested as a safe reagent to promote nerve regeneration in humans. Therefore, the goal of this Phase 2a clinical trial is to establish safety data and to examine the effect of PEG fusion on clinical outcomes including recovery of sensory and motor function. Results will be externally validated using data collected in the DoD funded prospective NERVE study and will provide preliminary evidence to power a larger phase II efficacy trial.

详细描述

The study will enroll 40 patients receiving autograft reconstruction within 24 hours of injury. Patients will be randomized to either PEG mediated reconstruction (n=20); or conventional nerve reconstruction (n=20). The investigators hypothesize that (1) the rate of complications within 1 month of surgery in patients treated with PEG fusion will be comparable to that of patients treated with conventional autograft reconstruction, (2) there will be no detrimental effects from PEG fusion on nerve regeneration over 2 years compared to patients treated with conventional nerve reconstruction, ((3) recovery of sensory and motor function will occur earlier (within 6 months) among patients treated with PEG fusion compared to patients treated with conventional autograft reconstruction (4) patients treated with PEG fusion will have better range of motion, greater hand strength, less disability, less pain, and higher rates of treatment satisfaction compared with patients treated with conventional autograft reconstruction.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Single (Participant)

入排标准

年龄范围
18 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Sustained a complete peripheral nerve injury resulting from upper extremity trauma presenting within 48 hours of injury
  • Involves injury or dysfunction to motor and/or sensory function of the axillary, radial, median, ulnar, or musculocutaneous nerve with injury localized between the proximal humerus and the distal flexion crease of the wrist
  • Involves a "mixed" nerve segment (i.e., involves a location of any of the above specified nerves that can be expected to have both sensory and motor axons present).

排除标准

  • Patients beginning surgery within hours after injury.
  • Injury to the brachial plexus nerves
  • Injury to the nerves distal to the distal flexion crease of the wrist
  • Injury that involves a distal extension of the parent nerve that is considered sensory only (superficial radial nerve, lateral antebrachial cutaneous nerve, etc.) or the posterior interosseus or anterior interosseus nerve distal to the midpoint of the forearm (i.e., distal to what can be considered the main motor branches of the PIN and AIN).
  • Previous peripheral nerve injury resulting from trauma, stroke, muscular, neurologic, or neuromuscular disorder
  • Documented psychiatric disorder that is expected to result in high probability of self-harm or interfere with study follow-up.
  • Severe problems with maintaining follow up (e.g., patients who are prisoners or homeless at time of injury or who are intellectually challenged without adequate family support).
  • Not expected to survive the next 30 days due to their injuries/health condition.
  • The subject has a known allergy to polyethylene glycol (PEG).
  • If any of the assessments cannot be done on the contralateral side (CL) or the MRCC sensory 2PD value is > 10 mm on the CL side during baseline period, the subject is a screen failure.
  • The subject is pregnant and/or is breastfeeding.
  • The subject has a significant medical comorbidity precluding immediate repair.
  • The subject is not able to strictly adhere to the rules of the current clinical protocol.

研究组 & 干预措施

Conventional nerve reconstruction

No Intervention

Conventional nerve reconstruction

PEG mediated reconstruction

Experimental

NTX-001 will be administered topically via isolation chamber medical device. Dose Unit: 2.5 mL NTX-001 is a single use surgical product intended for use as adjunct treatment in the repair of severed peripheral nerves in patients requiring standard suture neurorrhaphy.

干预措施: NTX-001 (Drug)

结局指标

主要结局

Complications or problems that occur with in the first 30 days.

时间窗: Up to 2 years

Complications or problems include surgical site infections, wound dehiscence/breakdown, exposure of nerves and/or their repairs and reconstructions, breakdown of nerve repair or reconstruction, seroma/hematoma requiring an additional procedure to treat, and any other local wound complications related to the zone of nerve injury that require an additional surgical procedure

次要结局

未报告次要终点

研究者

发起方
Major Extremity Trauma Research Consortium
申办方类型
Other
责任方
Sponsor

研究点 (14)

Loading locations...

相似试验

Evaluating the Safety and Efficacy of Polyethylene... | 临床试验