跳至主要内容
临床试验/NCT01399983
NCT01399983已完成不适用

Assessment of Exercise Capacity and Standardization of Six Minute Walk Test in Patients With Pulmonary Hypertension

Medical University of Graz1 个研究点 分布在 1 个国家目标入组 29 人开始时间: 2011年7月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
29
试验地点
1
主要终点
change of six minute walk distance between baseline measurement and measurement with more effort or less effort

研究概览

简要总结

The 6 minute walk (6MW) gives information about the exercise capacity and it is an important tool for clinical decisions and for the prognostic evaluation of PH patients. The test is technically simple to perform, inexpensive and reproducible. During the 6MW O2 saturation, heart rate, walking distance (in this study after every minute) and the level of dyspnea (BORG-dyspnea scale) may be recorded; however, at present, mainly the walking distance is evaluated. The test is sometimes criticized, because of the dependence on the patient's motivation.

The purpose of the present study is to standardize the test by the incorporation of objective factors. The investigators are correlating the change of heart rate and dyspnea (BORG scale) with the achieved walking distance during subsequent examinations performed with different effort.

详细描述

On two different days the patients have to absolve four 6MW on different levels of effort - on both days a traditional test will be performed and additionally a test with more effort or with less effort. The order of the tests will be randomized. These two days of the examinations should be within a maximum of three months, provided that there is no sign of relevant clinical changes. After every minute the walking distance is determined. Heart rate and the O2 saturation are measured by pulsoxymetry during the whole test. Every two minutes the patients are asked about their dyspnea (Borg scale).

The purpose of the present study is to standardize the test by the incorporation of objective factors and to detect the correlation between the walking distance and the level of effort during exercise. The investigators expect that the reliability and objectivity of 6MW may increase by the standardization.

The additionally performed cardiopulmonary exercise testing helps to evaluate and stratify patients.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 90 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • diagnosis of pulmonary hypertension or exercise-induced pulmonary hypertension by right heart catheterisation
  • informed consent

排除标准

  • Myocardiac Infarct within the last 12 months
  • Uncontrolled ventricular arrhythmia
  • Uncontrolled bradycardic or tachycardic supraventricular arrhythmia
  • relevant operations within the last 12 weeks
  • change of the hemodynamic therapy within the last 6 weeks
  • joint diseases or diseases of peripheral vessels and nerves which may make the results of the six minute walk test unreliable

结局指标

主要结局

change of six minute walk distance between baseline measurement and measurement with more effort or less effort

时间窗: the six minute walk test with a different effort is performed 1 hour after the baseline test. The second baseline test and the missing test with a different effort takes place within three months.

distance at six minute walk performed by different efforts

次要结局

未报告次要终点

研究者

发起方
Medical University of Graz
申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...