Risk of Bacterial Exposure to the Anesthesiologist's Face During Intubation and Extubation
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 66
- 试验地点
- 1
- 主要终点
- Bacterial growth of face shield swab after the endotracheal extubation
研究概览
简要总结
The practice of intubation and extubation is not without risks to the anesthesiologists. Especially, the face of health care worker is the body part most commonly contaminated by splashes and sprays of body fluids. The aim of this study is to determine the incidence of unrecognized exposure to the anesthesiologists' face during endotracheal intubation and extubation. We will perform face shield swab before and after the endotracheal intubation and extubation. All swabs will be cultured for 48 hours and the number of colony forming units before and after the procedures (intubation/extubation) will be compared.
研究设计
- 研究类型
- Observational
- 观察模型
- Case Only
- 时间视角
- Prospective
入排标准
- 年龄范围
- 20 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •anesthesiologists who perform endotracheal intubation and extubation for patients scheduled for endotracheal intubation for elective surgeries
排除标准
- 未提供
结局指标
主要结局
Bacterial growth of face shield swab after the endotracheal extubation
时间窗: Bacterial swab will be performed 5 minutes after the endotracheal extubation (after the confirmation of sufficient spontaneous breathing)
All swab will be cultured for 48 hours and will be reported as no growth or by number of colony forming unit(CFU)s. The number of CFU of post-extubation swab will be compared with that of pre-extubation swab.
次要结局
- Bacterial growth of face shield swab after the endotracheal intubation(Bacterial swab will be performed 5 minutes after the endotracheal extubation (after the confirmation of adequate mechanical ventilation))