跳至主要内容
临床试验/NCT06627920
NCT06627920已完成不适用

Validation of a Smartwatch for Blood Pressure Measurement

European University Miguel de Cervantes1 个研究点 分布在 1 个国家目标入组 101 人开始时间: 2024年7月10日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
101
试验地点
1
主要终点
Diastolic and systolic blood pressure

研究概览

简要总结

Accurate measurement of blood pressure is essential for the assessment of cardiovascular health and the prevention of cardiovascular disease. Smartwatches have emerged as a promising option for continuous monitoring of blood pressure outside the clinical setting. This study aims to validate the use of the smartwatch KC08 for blood pressure measurement, which is a cost-effective and convenient alternative for blood pressure measurement. A cross-sectional study will be conducted with participants aged greater than or equal to18 years. The measurements of blood pressure, heart rate and oxygen saturation will be performed with the smartwatch KC08, the Beurer PO30 pulse oximeter and the Omron M7 BP monitor. The statistical analysis will evaluate the reliability of the devices and compare the measurements of the two devices using different statistical methods.

研究设计

研究类型
Observational
观察模型
Other
时间视角
Cross Sectional

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Be ≥18 years old and able to understand the informed consent.

排除标准

  • A difference of ≥20 mmHg in systolic and/or diastolic blood pressure between both arms.

结局指标

主要结局

Diastolic and systolic blood pressure

时间窗: 5 minutes rest; 5 minutes safety BP measurements of both arms; 30 minutes BP measurements (10 measurements in total)

For BP measurement, an Omron M7 automatic blood pressure monitor (Omron Healthcare Co., Ltd., Kyoto, Japan) and a KC08 smartwatch (Mediatek Inc., Hsinchu, Taiwan) will be used. The participant should sit in a comfortable chair with lumbar support for at least 5 minutes prior to the measurement. The participant will be asked to place both feet flat on the floor, without crossing the legs, and rest the arm with the cuff on a table at chest level, palm up. Ensuring that the cuff is properly adjusted but not too tight and in contact with bare skin, the blood pressure will be measured. During this process, the subject should refrain from talking to ensure an accurate and reliable reading. The values obtained will be recorded according to standard blood pressure measurement procedures. 10 measurements separated by 1 minute will be taken with each device. The BP results will be recorded in mmHg.

Peripheral oxygen saturation

时间窗: 30 minutes (10 measurements in total)

A Beurer PO30 pulse oximeter (Beurer GmbH, Mittelstand, Germany) and a KC08 smartwatch (Mediatek Inc., Hsinchu, Taiwan) will be used. 10 measurements separated by 1 minute will be taken with each device. The peripheral oxygen saturation results will be recorded in percentage of hemoglobin saturation.

Physical activity levels

时间窗: 2 minutes

Participants' physical activity levels will be assessed using the International Physical Activity Questionnaire (IPAQ). This questionnaire consists of 7 questions that will help us stratify physical activity levels. It is used as a descriptive measure of the users and a possible confounding factor. It takes approximately 2 minutes to complete the questionnaire and we do it in the initial interview, before starting with the measurements of BP, heart rate and peripheral oxygen saturation.

Heart rate

时间窗: 30 minutes (10 measurements in total)

An Omron M7 automatic blood pressure monitor (Omron Healthcare Co., Ltd., Kyoto, Japan), a Beuer PO30 pulse oximeter and a KC08 smartwatch (Mediatek Inc., Hsinchu, Taiwan) will be used. Heart rate will be recorded while blood pressure measurements are being recorded. 10 measurements separated by 1 minute will be taken with each device. The heart rate results will be recorded in beats per minute (bpm).

次要结局

未报告次要终点

研究者

发起方
European University Miguel de Cervantes
申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...