临床试验/NCT02499796
NCT02499796已完成不适用

Short-term Effects of Humidification Devices on Respiratory Pattern and Work of Breathing During Invasive Ventilation

Fondazione Salvatore Maugeri2 个研究点 分布在 1 个国家目标入组 15 人开始时间: 2015年4月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
15
试验地点
2
主要终点
Change in muscle pressure-time product (PTPoes)

研究概览

简要总结

This study compares the short-term effects of a new humidification system (Hygrovent Gold) and two other humidification devices (heated and moisture exchanger and heated humidifier) on respiratory pattern and work of breathing, during invasive ventilation.

详细描述

Three humidifying devices are commonly and indifferently used during mechanical ventilation, but their impact on respiratory mechanics and, eventually, mechanical ventilation efficacy, particularly in patients highly dependent from mechanical ventilation, are not superimposable.

It has already been described that heated and moisture exchangers (HME), increasing dead space, can negatively affect ventilatory function and gas exchange, in comparison to heated humidifiers (HH).

The Hygrovent Gold, mainly because of its position between the tracheostomy and the Y-piece of the ventilatory circuit and its structure, may lead to analogous or even worse effects, determining and increase in inspiratory resistances and dead space and consequently an increase in the work of breathing.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Other
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Chronic hypercapnic respiratory failure (PaCO2 of 45 mmHg or more)
  • Long-term mechanical ventilation via tracheostomy
  • Clinical stability

排除标准

  • Non collaborative subjects
  • Acute respiratory failure
  • Haemodynamic instability
  • Encephalopathy

结局指标

主要结局

Change in muscle pressure-time product (PTPoes)

时间窗: Baseline and 60 minutes

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Annia Schreiber

MD

Fondazione Salvatore Maugeri

研究点 (2)

Loading locations...

相似试验

已完成
不适用
Comparison of two types of airway humidifier in ventilated patients on pulmonary parameters and infection ratesMoisturizers act in a ventilator like an artificial nose. Oxygen, along with the volume produced, which is a dry gas, is heated and humidified by Humidifier, and is passed to the patient's lungs. Without proper moisturizing, it can damage the lungs and increase lung parameters and even infection (Ventilator Associated Pneumonia) causing Prolonging the process of separating patients from the device..
IRCT20171202037703N1Zanjan University of Medical Sciences80
已完成
不适用
The impact of different humidification techniques in newly tracheotomized patients - an ex vivo studyZ93.0Tracheostomy status
DRKS00004865niversitätsklinikum Mannheim20
已完成
不适用
To investigate the effect of the humidifying device in a driving simulator on driving performance and visual functio
JPRN-UMIN000015535Department of Ophthalmology, Keio University School of Medicine16
已完成
不适用
High flow humidified nasal oxygen versus face mask oxygen for preoxygenation of pregnant women – a prospective randomised controlled crossover studyPregnancyPreoxygenationAnaesthesiology - AnaestheticsReproductive Health and Childbirth - Childbirth and postnatal careRespiratory - Normal development and function of the respiratory system
ACTRN12619000620123Department of Anaesthesia, The Royal Women's Hospital - Parkville70
终止
不适用
Gases Humidification During Noninvasive Ventilation : Heat and Moisture Exchanger or Heated Humidifier ?PneumoniaAcute Heart FailureAcute Lung InjuryChronic Obstructive Pulmonary Disease
NCT00221819University Hospital, Bordeaux
Short-term Effects of Humidification Devices on... | 临床试验