跳至主要内容
临床试验/NCT02577835
NCT02577835已完成不适用

International Registry for Ambulatory Blood Pressure and Arterial Stiffness Telemonitoring

Italian Institute of Telemedicine24 个研究点 分布在 10 个国家目标入组 2,000 人开始时间: 2015年11月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
2,000
试验地点
24
主要终点
24-hour Pulse Wave Velocity (PWV)

研究概览

简要总结

This Registry is an investigator-initiated, international, multicenter, observational, prospective study aiming at: i) evaluating non-invasive 24-h ambulatory blood pressure and arterial stiffness estimates (through 24-h pulse wave analysis) in hypertensive subjects; ii) assessing the changes in estimates following treatment; iii) weighing the impact of 24-h pulse wave analysis on target organ damage and cardiovascular prognosis; iv) assessing the relationship between arterial stiffness, blood pressure absolute level and variability, and prognosis. Approximately 2000 subjects, referred to 20 hypertension clinics for routine diagnostic evaluation and follow-up of hypertension, will be recruited. Data collection will include ambulatory blood pressure monitoring, performed with a device allowing simultaneous non-invasive assessment of blood pressure and arterial stiffness, and clinical data (including cardiovascular outcomes). A web-based telemedicine platform will be used for data collection. Subjects will visit the centers at 6-12 month intervals. First follow-up results are expected to be available in the next 2-years. The results of the Registry will help defining the normalcy thresholds for current and future indices derived from 24-h pulse wave velocity, according to outcome data. They will also provide supporting evidence for the inclusion of such evaluation in recommendations on hypertension management.

详细描述

The VASOTENS Registry is an international, multicenter, observational, prospective project Actually, it is a large database of ambulatory blood pressure recordings obtained with a non-invasive device, able to determine central blood pressure and various indices of arterial stiffness (mainly pulse wave velocity and augmentation index) over the 24-hours, based on a clinically validated technology of pulse wave analysis of oscillometric blood pressure measurements, integrated in an ambulatory blood pressure monitor. Specifically, this project aims at creating an international network of centers performing ambulatory blood pressure monitoring and arterial stiffness monitoring, in order to evaluate the impact of such estimates on the clinical outcome of hypertensive patients. The results of the data collected at baseline and during regular follow-up of hypertensive patients (up to 2 years) will help to provide evidence on the clinical usefulness of such technologies for the screening and follow-up of the hypertensive patients. The registry will include data from subjects fulfilling the inclusion criteria and whose data are contained in existing databases collected by the participating centers and who are regularly followed-up at the center. New subjects can be enrolled for this project, but they must be submitted to ambulatory blood pressure monitoring because it is required for evaluating their hypertension status, according to current recommendations. Data collection is ensured by a dedicated web-based telemedicine platform, including an electronic case report form (e-CRF). The e-CRF allows collection of patient's clinical data, such as family history, anthropometric data, habits, past and current diseases, therapies, office blood pressure, and laboratory tests, including evaluation of target organ damage. The project does not involve any type of intervention related to the study and the physicians can manage the patients included in the Registry according to the requirements of clinical practice and current guidelines. However, as recommended by current guidelines, each patient has to be followed-up with visits occurring at regular intervals (ideally every 6 months, and not less than once a year). The physicians is also free to use the ambulatory blood pressure data in the clinical management of the patients. At least 30 Hypertension centers are planned to be involved in the project, each one providing at least 100 patients, which have to be followed-up over time. Centers will be selected in different countries, initially in Europe, starting from Italy and Russia. Mandatory criteria of a center to be included in the study are the availability in the facility of a BPLab ambulatory blood pressure monitor, the potential for providing and properly following-up the number of patients required by the protocol, the availability of Internet connection, regular access to the web and human resources to upload ambulatory blood pressure and clinical data.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Subjects referred to routine diagnostic evaluation for hypertension or established hypertensive subject
  • ABPM performed for clinical reasons with a BPLab device
  • Valid ambualtory blood pressure recordings (interval between measurements not >30 minutes, at least 70% of expected number of readings, at least 20 valid readings during the day-time and 7 during the night-time)
  • Availability of individual measurements for ambulatory blood pressure monitoring
  • Availability of basic demographic and clinical information
  • Availability of a signed informed consent form

排除标准

  • Age <18 years
  • Atrial fibrillation, frequent ectopic beats, second or third degree atrioventricular blocks, or other conditions which might make difficult or unreliable the automatic blood pressure measurement with the oscillometric technique
  • Upper arm circumference <22 cm
  • Pregnancy

结局指标

主要结局

24-hour Pulse Wave Velocity (PWV)

时间窗: 2 years

24-hour average value for arterial stiffness was assessed through estimation of the time traveled by the pulse wave from the central arterial tree (aorta) to the peripheral arteries (brachial artery) and measured in meters per sec. The faster the wave travels through the arterial tree, the stiffer the artery is.

24-hour Augmentation Index (AI)

时间窗: 2 years

24-hour average value for waves reflection expressed as a percentage. The augmentation index is a measure of wave reflection and arterial stiffness and is commonly measured as the ratio of the central pulse pressure and the reflected pulse pressure which augments the central blood pressure. When arteries are stiff, a reflected wave is formed where arteries split. This reflected wave moves back at the heart and increases the pressure at which the heart has to pump. The higher the index the stiffer the artery is.

24-hour Central Blood Pressure

时间窗: 2 years

24-hour average central aortic pressure expressed in mmHg, as the estimated blood pressure at the level of the thoracic aorta

次要结局

  • 24-hour Systolic Blood Pressure(2 years)
  • 24-hour Diastolic Blood Pressure(2 years)
  • Cardiac Damage (Left Ventricular Hypertrophy at Echocardiogram or ECG)(2 years)
  • Vascular Damage (Carotid Plaque at Ultrasonography)(2 years)
  • Renal Damage (Urine Protein)(2 years)
  • Combination of Non-fatal and Fatal CV and Renal Events or All-cause Death(4 years)

研究者

发起方
Italian Institute of Telemedicine
申办方类型
Other
责任方
Sponsor

研究点 (24)

Loading locations...

相似试验