跳至主要内容
临床试验/NCT05054452
NCT05054452已完成不适用

Predicting Fluid Responsiveness in Mechanically Ventilated Critically Ill Children and Neonates Using Transthoracic Echocardiography

Assistance Publique - Hôpitaux de Paris2 个研究点 分布在 1 个国家目标入组 4 人开始时间: 2021年6月25日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
4
试验地点
2
主要终点
Cardiac index measured by transthoracic echocardiography

研究概览

简要总结

Initial fluid resuscitation remains the first treatment step for most children experiencing circulatory failure and/or systemic hypotension. Only one-half of these patients respond to fluid administration by a significant increase in cardiac output. A positive fluid balance is a poor prognostic factor that increases mortality. There are few markers validated in children to assess volume reactivity by dynamic ultrasound parameters mainly based on heart-lung interaction.

In this work, the investigators propose to investigate whether dynamic parameters validated in adults, such as the superior vena caval collapsibility and the variability of cardiac output during an end-expiratory and end-inspiratory occlusion, are also reliable indicators of volume responsiveness in sedated children under controlled-mode ventilation.

详细描述

After standardized volume expansion, patients who present an increase of cardiac index measured by transthoracic echocardiography greater than or equal to 15% of baseline measurement will be considered responders .

A previous similar study using respiratory variations in aortic blood flow to predict fluid responsiveness in ventilated children reported a ROC curve area 0.85, while the prevalence rate of circulatory failure was 50%. Given these assumptions, a sample size of 38 subjects per group (Responders / No responders) was estimated to provide a AUC equivalent. A total of 76 subjects should be included.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
— 至 17 Years(Child)
性别
All
接受健康志愿者

入选标准

  • Patient < 18 years (child and neonate)
  • Sedated and mechanically ventilated under controlled-mode ventilation
  • In whom fluid administration was planned by the attending physicians

排除标准

  • High-frequency oscillatory ventilation
  • Cardiac arrhythmia
  • Congenital heart defect

研究组 & 干预措施

Echocardiographic assessment

Experimental

At baseline before standardized volume expansion, a first set of echocardiographic measurements will be performed. Then, we will perform 15-second end-expiratory and end-inspiratory occlusions. Occlusions will be separated by 1 minute to allow the cardiac index to return to its baseline value. A last set of measurements will be performed after fluid administration. Ventilatory settings and other treatments will remain unchanged during the study period.

干预措施: Echocardiographic assessment (Device)

结局指标

主要结局

Cardiac index measured by transthoracic echocardiography

时间窗: Through the end of the hospitalisation, a maximum of 2 months

After fluid administration, patients who present an increase of cardiac index measured by transthoracic echocardiography greater than or equal to 15% of baseline measurement will be considered responders .

次要结局

  • End-tidal carbon dioxide levels(Through the end of the hospitalisation, a maximum of 2 months)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验