跳至主要内容
临床试验/NCT06801392
NCT06801392招募中不适用

The Acute Efficacy and Safety of Left Atrial Posterior Wall and Mitral Isthmus Ablation in Patients With Non-Paroxysmal Atrial Fibrillation

Charles University, Czech Republic1 个研究点 分布在 1 个国家目标入组 50 人开始时间: 2025年1月1日最近更新:

试验速览

阶段
不适用
状态
招募中
发起方
入组人数
50
试验地点
1
主要终点
Serum Neutrophil Gelatinase-Associated Lipocalin Concentration

研究概览

简要总结

An observational study evaluating efficacy and safety of the Varipulse catheter in pulsed-field ablation of atrial fibrillation

详细描述

Background: Pulmonary vein (PV) isolation (PVI) is the cornerstone of catheter-based treatment of atrial fibrillation (AF). The left atrial posterior wall (LAPW) and mitral isthmus (MI) are potential ablation targets in patients with non- paroxysmal atrial fibrillation. The efficacy of PVI, LAPW, and MI ablations in early studies of pulse field ablation (PFA) using pentaspline PFA catheters (Farawave, BSCI) or, recently, PVI using a variable-loop circular catheter (Varipulse, Biosense) have been excellent. Complete PV isolation was achieved after first-pass ablation in almost 100% of PVs. Concerning the Farawave catheter, the majority of centers perform empiric pulsed-field PVI, using standard recommended configurations and power settings for ablation catheters, but without verifying PVI (or other lesion using a standard Lasso catheter for and voltage and activation mapping). The praxis regarding LAPW and MI ablations differs significantly among centers; while some centers routinely verify mitral isthmus block using a CS catheter and stimulation maneuvers, others perform anatomicaly-guided MI ablations without block verification by stimulation maneuvers. The ADVENT trial showed that radiofrequency and PF ablations have similar efficacy. However, several cases of PV, LAPW, and MI reconnections have been reported (either acutely or during redo procedures) after ablations using Farawave ablation catheters. In our experience, the efficacy of first-pass PVI using Farawave ablation PF catheters is ~96% (when PV-isolation was verified using a standard Lasso catheter after ablation, data under review). In comparison, first-pass MI block is about ~ 60% (verified using pacing from the left atrial appendage, data under review). Regarding the Varipulse catheter, which recently received the CE mark, efficacy data on PV, LAPW, and MI ablations remains scarce. This raises the question of whether anatomicaly- guided LA ablations (i.e., fluoroscopy and ICA navigation with the recommended ablation setup) should be considered less desirable than LA ablations in which PVI, LAPW, and MI block are verified with additional mapping. With regard to LAPW ablation, the results with pulsed-filed ablation are excellent, and LAWP was isolated in the majority of cases. On the other hand, regarding MI block and based on our previous experience with MI ablations, the probability that a complete block is achieved based solely on an empiric ablation (without verification using either differential pacing, or optimally using 3D mapping) is not high. The advent of the Varipulse system allows for high-power ablations using PF energy combined with 3D mapping capability. As such, it presents a unique opportunity to verify ablation lesions, i.e., verifying the completeness of PVI, LAPW and MI block and locating the most common sites of gaps. Information about the success rate of Varipulse in achieving a complete first-pass LAPW isolation, and MI block, and potentially identifying gaps in the LAPW or in the absence of a MI block could increase first-pass ablation success rates. Regarding LAPW, since an excessive number of PF application could lead to extensive hemolysis or even to worsening of renal function (see below), information about the minimum number of PF energy applications that will already be associated with complete LAPW isolation (complete line between right and left PVs) is of importance. After an initial excellent safety profile for PFA, as more experience was gained with the method, some potential renal issues associated with PFA began to appeared. Recently, a case of renal failure due to hemolysis after PFA using a Farapulse was described. All cases of renal failure occurred after a large number (more than 120) of PF applications using the Farapulse system. The hemolysis is present during pulsed-field ablation, and as our and also other recent data indicates, the amount of hemolysis correlates with the number of PF applications (using Farapulse system). In the study conducted by the investigators, the concentration of red blood cell microparticles (i.e., fragments of destroyed erythrocytes) and other markers hemolysis (e.g. lactate dehydrogenase) correlated with the number of PF applications using Farapulse system. Since the information on hemolysis is new, the "safe" threshold, i.e. the safe number of PF energy application has been still not established. Moreover, since the impulse characteristics differ between different PF systems, it is unclear whether our Farapulse system data can be easily transferred to other PF generators with different pulse characteristics. Determining the amount of hemolysis, renal function and activation of platelets and coagulation after PF ablations using a Varipulse system is the second (safety) part of this project.

Objective: (1) to assess the efficacy of ablation of LAPW and to determine the location of typical gaps after LAPW, (2) to assess the efficacy of ablation of MI and to determine the location of typical gaps after MI, (3) to assess hemolysis during Varipulse ablations, and (4) to analyze activation of thrombotis during Varipulse ablation

Methods: Fifty patients with non-paroxysmal AF will be enrolled. Inclusion criteria will be:

  1. non-paroxysmal atrial fibrillation,
  2. an indication for catheter ablation according current guidelines,
  3. willingness to sign informed content.

Exclusion criteria will be hematological disorders that can be associated with spontaneous hemolysis, chronic kidney disease stage 3 or worse, previous left atrial ablation (either using pulsed-field or radiofrequency energy), conditions associated with increased inflammation (COPD III or more, vasculitis etc.).

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • non-paroxysmal atrial fibrillation
  • an indication for catheter ablation according current guidelines
  • willingness to sign informed content.

排除标准

  • hematological disorders that can be associated with spontaneous hemolysis
  • chronic kidney disease stage 3 or worse
  • previous left atrial ablation (either using pulsed-field or radiofrequency energy)

结局指标

主要结局

Serum Neutrophil Gelatinase-Associated Lipocalin Concentration

时间窗: Blood samples will be taken (1) at the beginning of the procedure from the femoral vein and (2) in the morning on the day after the procedure.

Serum neutrophil gelatinase-associated lipocalin (NGAL).

Red Blood Cell Microparticles

时间窗: Blood samples will be taken (1) at the beginning of the procedure from the femoral vein, (2) at the end of all ablations before sheath removal, and (3) in the morning on the day after the procedure.

The concentration of red blood cell microparticles (using flow cytometry).

Lactate Dehydrogenase

时间窗: Blood samples will be taken (1) at the beginning of the procedure from the femoral vein, (2) at the end of all ablations before sheath removal, and (3) in the morning on the day after the procedure.

Serum lactate dehydrogenase will be determined.

Platelet Activation Markers

时间窗: Blood samples will be taken (1) at the beginning of the procedure from the femoral vein, (2) at the end of all ablations before sheath removal, and (3) in the morning on the day after the procedure.

The platelet activation markers (CD62P, CD42b and PAC-1) will be determined

Prothrombosis Fragments

时间窗: Blood samples will be taken (1) at the beginning of the procedure from the femoral vein, (2) at the end of all ablations before sheath removal, and (3) in the morning on the day after the procedure.

Prothrombin fragments will be determined

Platelet-Thrombotic Microparticles

时间窗: Blood samples will be taken (1) at the beginning of the procedure from the femoral vein, (2) at the end of all ablations before sheath removal, and (3) in the morning on the day after the procedure.

Platelet-thrombotic microparticles will be determined

Acute Success of the Left Atrial Posterior Wall Ablation

时间窗: during the procedure

After the last application of PE energy, and after a 20-minute wait, all lesions will be verified by careful 3D-electro-anatomical mapping (voltage and activation mapping) and by conventional pacing manoeuvres.

Acute Success of the Mitral Isthmus Ablation

时间窗: during the procedure

After the last application of PE energy, and after a 20-minute wait, all lesions will be verified by careful 3D-electro-anatomical mapping (voltage and activation mapping) and by conventional pacing manoeuvres.

Serum Creatinine Concentration

时间窗: Blood samples will be taken (1) at the beginning of the procedure from the femoral vein and (2) in the morning on the day after the procedure.

Serum creatinine concentration

Serum Cystatin C Concentration

时间窗: Blood samples will be taken (1) at the beginning of the procedure from the femoral vein and (2) in the morning on the day after the procedure.

Serum cystatin C concentration.

次要结局

未报告次要终点

研究者

发起方
Charles University, Czech Republic
申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验