A Simple Technique to Reduce the Pain in Hysterosalpingography Using A Thin Catheter
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 70
- 试验地点
- 2
- 主要终点
- pain score during introduction of catheter and during the injection of dye
研究概览
简要总结
The investigators will use a thin catheter for HSG and apply pressure on the cervix with the vaginal speculum to prevent leakage of the dye during injection to study the uterine cavity and fallopian tubes and reduce the pain as compared to a standard metal cannula.
详细描述
Hysterosalpingography (HSG) remains one of the most reliable methods to study tubal patency and the uterine cavity (1-3). The relative indications and importance of HSG and laparoscopy in the diagnosis of tubal factor infertility have been extensively discussed. Recently a multicenter randomized controlled trial (4) has demonstrated that the routine use of HSG at an early stage of infertility work up, prior to laparoscopy and dye, does not influence the cumulative pregnancy rate compared with the routine use of laparoscopy and dye alone. However, HSG is an efficient method which is less invasive and less costly than laparoscopy (5), and than transvaginal hydrolaparoscopy (6). The main disadvantages of HSG are being unable to confirm adhesions, endometriosis and being a painful procedure (7,8). Different cannulas and catheters have been tried to reduce pain such as the Rubin cannula (9), Jorcho cannula (10), and Whitehead cannula or Foley catheter (11). Minimal difference in the degree of pain was found when the balloon catheter was compared with the cervical cup (12). General and local medications have been tried to alleviate pain during the procedure. (3,13).
HSG is widely practiced in our country, however, for cost effective reasons, the standard metal cannula is the only method used at our hospital. It is painful procedure because it requires grasping the cervix with a tenaculum and inducing some cervical dilatation during introduction of the cannula. The aim of this pilot study was to develop a simple and painless technique for HSG using a thinner than normal catheter, and without grasping the cervix with a tenaculum. Leakage of the dye through the cervix was prevented by pressing on the portiovaginalis of the cervix using the vaginal speculum. This technique for performing HSG is a novel one and has not been described previously in the medical literature.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 40 Years(Adult)
- 性别
- Female
- 接受健康志愿者
- 否
入选标准
- •infertile women during their fertility workup and requesting to do hysterosalpingography
排除标准
- •women with pelvic inflammatory disease
结局指标
主要结局
pain score during introduction of catheter and during the injection of dye
时间窗: 3-6 month
the efficiency of the new technique in filling the uterine cavity with the dye and studying fallopian tubes
时间窗: 3-6 month
次要结局
- adverse events(within the study period)