跳至主要内容
临床试验/NCT03524313
NCT03524313Unknown不适用

Assessment of Cardiac Output With End-tidal Carbon Monoxide

Centre Hospitalier Universitaire de Besancon1 个研究点 分布在 1 个国家目标入组 75 人开始时间: 2020年1月1日最近更新:
适应症

试验速览

阶段
不适用
入组人数
75
试验地点
1
主要终点
Correlation between cardiac output (VTI) and EtCO2

研究概览

简要总结

Hemodynamic monitoring, especially cardiac output assessment, is a key feature for the management of critically ill patients. Although the use of invasive methods, such as thermodilution with a pulmonary artery catheter, remains the GOLD standard for the evaluation of the cardiac output, several non-invasive techniques are currently used in practice. An acceptable estimation of the cardiac output can be made by standard transthoracic echocardiography. Cardiac output can be calculated from subaortic velocity time integral (VTI). However, this technique requires a trained operator and depends on the echogenicity of the patient. The best method for assessing cardiac output depends on the patient's needs, the clinical scenario and the physician's experience with the monitoring device itself. No simple and rapid tool currently exist for assessing cardiac output in critically ill patients.

The measurement of end-tidal carbon dioxide (EtCO2) used in routine in critically ill patients requiring mechanical ventilation could be an interesting alternative. Indeed, the amount of carbon dioxide (CO2) exhaled depends on the production of CO2 by the body, the pulmonary blood flow (corresponding to cardiac output) and its elimination by alveolar ventilation. In controlled ventilation, ie for constant alveolar ventilation, EtCO2 should therefore depend only on cardiac output. It has been shown in a porcine model that EtCO2 and cardiac output are strongly related under stable respiratory and metabolic conditions. In humans, only the variation of EtCO2 after volume expansion has been studied and EtCO2 seems to reflect changes in cardiac output. Nevertheless, the usefulness of EtCO2 in assessing cardiac output has never been evaluated.

The objective of this study is therefore to determine the relationship between EtCO2 and cardiac output evaluated by the measurement of subaortic VTI in critically ill patients.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • patients intubated and ventilated in the control assisted mode with no inspiratory effort
  • requiring vasopressors

排除标准

  • less than 18 years
  • refuse to participate
  • situation in which health condition, medication or procedure could significantly interfere with the interpretation of EtCO2 or cardiac output (extracorporeal life support, pneumothorax with persistant air leak)
  • (be increased without correlation to an infectious process (poly-traumatised patients,

结局指标

主要结局

Correlation between cardiac output (VTI) and EtCO2

时间窗: between 0 to 3 day after ICU admission

ITV ≈ (FR x EtCO2)/PaCO2

次要结局

  • Correlation between cardiac output (VTI) and portal veinous velocity(between 0 to 3 day after ICU admission)
  • Increase the sensitivity for detection of low cardiac output by using EtCO2(between 0 to 3 day after ICU admission)
  • Comparison between cardiac output (VTI) and femoral veinous velocity(between 0 to 3 day after ICU admission)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...