跳至主要内容
临床试验/NCT03008642
NCT03008642已完成不适用

CO-Rebreathing in Comparison to Isotopic Red Cell Volume Determination in the Diagnosis of Primitive and Secondary Polycythemia: a Multicentric Study. Co-Rebreathing for the Measurement of Total Red Cell Mass in Polycythemia.

Centre Hospitalier Universitaire, Amiens2 个研究点 分布在 1 个国家目标入组 60 人开始时间: 2019年4月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
60
试验地点
2
主要终点
equivalence of RCM determination by CO-Rebreathing in comparison to the traditional isotopic measurement in the diagnosis of polycythemia

研究概览

简要总结

The optimized CO-Rebreathing is an efficient method to evaluate the red cell mass and has been used in the vast majority of studies in sport medicine. However, this method has never been evaluated on a large scale in the diagnosis of primitive or secondary polycythemia. The standard procedure to evaluate the red cell mass is based on isotopic measurement using Cr51-labelled red cells, but its lack of availability in many centers highlights the need for a non-invasive and rapid alternative method. The purpose of this study is to evaluate and validate the CO-Rebreathing method in this set of indications.

详细描述

The definition of a true polycythemia is stricto sensu an increased red cell mass (RCM) above 125% of the expected value depending on the size and the weight of the patient. However, this measurement requires an isotopic labeling of red cells and is not available in most of the hospitals. Therefore, the diagnosis of polycythemia, and particularly Polycythemia Vera (PV) is based on routine red blood cells parameters, i.e. hemoglobin level and hematocrit. If these parameters are efficient in marked polycythemia, discrepancies have been observed in milder cases. Two situations where a RCM evaluation is particularly required can be described:

  • In patients with a hematocrit level between 52 and 60% (men) or between 48 and 56% (women) in order to limit invasive investigations to patients with a confirmed polycythemia diagnosis
  • In JAK2V617F positive myeloproliferative neoplasms (MPN) with hematocrit and hemoglobin levels under the PV cut-off in order to discriminate between masked PV and essential thrombocythemia CO-Rebreathing is a fast, non invasive alternative method for RCM evaluation. It is based on the high affinity of carbon monoxide (CO) for hemoglobin. The decrease in the HbCO percentage after CO inhalation is dependent on the total hemoglobin mass from which RCM can be obtained. The investigators propose a tri-centric study evaluating CO-Rebreathing as an alternative tool to measure RCM in the diagnosis of polycythemia in the two categories of patients described above.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Prevention
盲法
None

入排标准

年龄范围
18 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Adult patient
  • Informed consent obtained
  • Requirement of an isotopic red cell mass determination:
  • a - Hematocrit between 52 and 60% (men) or 48 and 56% (women) with no argument for a PV (JAK2V617F negative, EPO level normal/high).
  • b - Patients with a JAK2V617F positive MPN and a hematocrit level between 46 and 50% (women) or 48 and 52% for men.
  • No recent vascular event (<6 mois)
  • No unstable coronaropathy
  • Non smoking since 24 hours.
  • Negativity of pregnancy test/effective contraception for childbearing age women,
  • Health insurance

排除标准

  • Recent venous event <1 months, cerebral stroke < 6 mois)
  • Evolutive cardiopathy (< 6 months)
  • Chronic Respiratory failure
  • Smokers with no withdrawal in the last 24 hours before CO-Rebreathing
  • Basal HbCO>7% the day of CO-Rebreathing
  • Pregnant or breast feeding women
  • Patient enable to give an informed consent
  • Inclusion in an interventional clinical trial in the last three months.
  • Any contraindication to lung function testing

结局指标

主要结局

equivalence of RCM determination by CO-Rebreathing in comparison to the traditional isotopic measurement in the diagnosis of polycythemia

时间窗: 1 month

The primary outcome is to prove the equivalence of RCM determination by CO-Rebreathing in comparison to the traditional isotopic measurement in the diagnosis of polycythemia.

次要结局

  • AE / SAE / EI(1 month)
  • Cumulative incidence of thrombotic and hemorrhagic complications(1 month)
  • Deaths and causes(1 month)
  • Analysis of the results of VGTCO and VGTi(1 month)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验