跳至主要内容
临床试验/NCT06656884
NCT06656884进行中(未招募)不适用

FARAPULSE Workflow Assessment Registry

Boston Scientific Corporation59 个研究点 分布在 11 个国家目标入组 524 人开始时间: 2025年5月6日最近更新:

试验速览

阶段
不适用
状态
进行中(未招募)
入组人数
524
试验地点
59
主要终点
Association of patient demographics with Index procedure Workflow-related variables

研究概览

简要总结

The study is designed to determine the best practices in the patient pathway, and to analyze pre-procedural, procedural and follow-up workflow data related with ablation of atrial fibrillation where the FARAPULSE™ Pulsed Field Ablation System is used in a commercial and standard of care setting. Workflow-related variables, inclusive of pre-procedural imaging, methods of transseptal access, anesthesia/sedation technique, intracardiac mapping, ablation settings, dosing strategy, lesion sets and general procedure management, will be used to identify predominant workflow schemes that will be associated with patient demographics, procedure-related complications (safety parameters), and one-year effectiveness parameters.

The study data can be used for procedural workflow optimization when using Pulsed Field Ablation for the ablation treatment of Atrial Fibrillation based on patient demographics, cardiac anatomy and arrhythmia characteristics.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Subjects are prospectively planned and intended to be treated with the FARAPULSE™ Pulsed Field Ablation system for cardiac tissue ablation, per physician's medical judgement, and as per hospitals' standard of care
  • Subjects who are willing and capable of providing informed consent
  • Subjects who are willing and capable of participating to this Registry at an approved clinical investigational center
  • Subjects whose age is 18 years or above, or who are of legal age to give informed consent specific to state and national law

排除标准

  • Subjects who are currently enrolled in another investigational study or registry that would directly interfere with the current study. Exceptions are when the subject is participating in a mandatory governmental registry, or a purely observational registry, that do not interfere with the current study
  • Prior Left Atrium Ablation

结局指标

主要结局

Association of patient demographics with Index procedure Workflow-related variables

时间窗: Index Procedure

Patient demographics such as age (years), gender, BMI (kg/m²), different comorbidities, LA Volume (ml), PV anatomy, AF type, pre-procedural AF management) will be compared with different index procedure workflow related variables such as pre-procedural imaging, method and location of transseptal access, intracardiac electro-anatomical mapping, imaging techniques, anesthesia/sedation technique, ablation settings, dosing strategy, lesion sets and general procedure management

Association of safety parameters with Index procedure Workflow-related variables

时间窗: 12 months

Safety parameters such as device or procedure related serious adverse events (within 7 days onset date) Death; Myocardial Infarction; Stroke; TIA; Peripheral or Organ Thromboembolism; Pulmonary Edema; Unresolved Phrenic Nerve Palsy/Paresis at 12 Months post-Index Procedure; Vascular Access Complications; Heart Block; Gastric Motility / Pyloric Spasm Disorders, Cardiac Tamponade / Perforation; Pericarditis; Severe Hemolysis with Subsequent Renal Injury or Significant Anemia / Within 12 Months onset date: Pulmonary Vein Stenosis; Atrio-Esophageal Fistula) will be compared with different index procedure workflow related variables such as pre-procedural imaging, method and location of transseptal access, intracardiac electro-anatomical mapping, imaging techniques, anesthesia/sedation technique, ablation settings, dosing strategy, lesion sets and general procedure management

Association of effectiveness parameters with Index procedure Workflow-related variables

时间窗: 12 months

Acute and long-term (freedom from AF episodes and freedom from intervention for AF/AFL/AT) Effectiveness parameters will be compared with different index procedure workflow related variables such as pre-procedural imaging, method and location of transseptal access, intracardiac electro-anatomical mapping, imaging techniques, anesthesia/sedation technique, ablation settings, dosing strategy, lesion sets and general procedure management

Association of patient demographics with effectiveness parameters

时间窗: 12 months

Patient demographics such as age (years), gender, BMI (kg/m²), different comorbidities, LA Volume (ml), PV anatomy, AF type, pre-procedural AF management) will be compared with Acute and long-term (freedom from AF episodes and freedom from intervention for AF/AFL/AT) Effectiveness parameters

Association of patient demographics with safety parameters

时间窗: 12 months

Patient demographics such as age (years), gender, BMI (kg/m²), different comorbidities, LA Volume (ml), PV anatomy, AF type, pre-procedural AF management) will be compared with Safety parameters such as device or procedure related serious adverse events (within 7 days onset date) Death; Myocardial Infarction; Stroke; TIA; Peripheral or Organ Thromboembolism; Pulmonary Edema; Unresolved Phrenic Nerve Palsy/Paresis at 12 Months post-Index Procedure; Vascular Access Complications; Heart Block; Gastric Motility / Pyloric Spasm Disorders, Cardiac Tamponade / Perforation; Pericarditis; Severe Hemolysis with Subsequent Renal Injury or Significant Anemia / Within 12 Months onset date: Pulmonary Vein Stenosis; Atrio-Esophageal Fistula)

次要结局

未报告次要终点

研究者

申办方类型
Industry
责任方
Sponsor

研究点 (59)

Loading locations...

相似试验