NCT06674967尚未招募不适用
Efficacy and Safety of Left Bundle Area Pacing Vs Right Ventricular Apical Pacing in Patients with Atrioventricular Block
适应症
试验速览
- 阶段
- 不适用
- 状态
- 尚未招募
- 入组人数
- 42
- 试验地点
- 1
- 主要终点
- effectiveness with LBB pacing
研究概览
简要总结
This study will address whether LBBaP is superior to RVAP in terms of safety and efficacy
详细描述
- Cardiac pacing is an effective therapy for treating patients with bradycardia due to sinus node dysfunction or atrioventricular block. However, traditional right ventricular apical pacing (RVAP) causes electric and mechanical desynchrony, increasing the risk for atrial arrhythmias and heart failure.
- .Cardiac resynchronization therapy(CRT)is another pacing modality employed for treatment of HF .Clinical studies have demonstrated that CRT promotes left ventricular reverse remodelling and reduces morbidity and mortality in patients with HF . Although CRT's benefits are well demonstrated, the therapy has been associated with significantly high non-response rate(30-40%).Also, the BVP is a non-physiological approach that requires two leads to activate the ventricular myocardium and not the specialized conduction system
- Therefore, there is a need to develop a physiological pacing approach that provides synchronized contraction of the ventricles
- Although His bundle pacing (HBP)has been widely used as a physiological pacing modality, it is limited by challenging implantation technique, unsatisfactory success rate in patients with wide QRS wave, high pacing capture threshold, and early battery depletion.
- Recently, the left bundle branch pacing (LBBP), defined as the capture of the left bundle branch (LBB) via trans ventricular septal approach, has emerged as a new physiological pacing modality.
- this approach has been found to provide physiological pacing that guarantees electrical synchrony of the left ventricle with a low pacing threshold.
- LBBP implantation is done by The Select Secure lead (model 3830) and Select Site C315HisorC304His sheaths are used in operation, while an electrophysiological multichannel recorder is used to simultaneously document intracardiac EGMs and 12-lead ECG .the Pacing System Analyzer (PSA) is used to test the pacing parameters and record intracardiac EGMs. The operation process can be summarized as follows: (1) establishment of the venous access and determination of the initial LBBP site; (2) introducing a pacing lead into the right ventricle and screwing it into the interventricular septum(IVS) until it reached in the LBB areas;(3) assessing the lead depth into ventricular septum and confirming LBB capture; (4)removing the sheath and providing the slack; and(5)programming the pulse generator.
- There is a limited number of clinical studies, featuring small sample sizes, that have shown that, compared with right ventricular apex pacing (RVAP), the QRS duration of postoperative ECG in LBBaP patients is narrower and the cardiac systolic function is improved. Also, there have been limited number of randomized controlled trials (RCTs) evaluating the efficacy and safety of LBBaP in patients with atrioventricular block (AVB) versus those with RVAP.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- 未提供
排除标准
- •Failure to cooperate with follow-up.
- •Persistent atrial fibrillation.
- •Patients with heart failure (LVEF) ≤35%,
- •Estimated glomerular filtration rate less than 30 ml/min.
- •Septic shock
- •advanced malignant tumor.
- •Pregnancy or prepared to get pregnant
- •Cardiac tamponade or major hemopericardium
结局指标
主要结局
effectiveness with LBB pacing
时间窗: 3 years
Assess left ventricular global strain using speckle tracking echocardiography (percentage)
Incidence of adverse events in patient with LBB pacing
时间窗: 3 years
Malignant arrhythmia(Yes/No)
Incidence of septal perforation
时间窗: 3 years
Detect septal perforation(Yes/No)
次要结局
- Major Adverse Cardiovascular Events(3 years)
研究者
Karim Mohamed Eltaher Abdelrahman Aly
Assistant lecturer
Assiut University
研究点 (1)
Loading locations...
相似试验
招募中
不适用
LEft Bundle branchArea Pacing to Avoid Pacing-induced CARdiomyopathyBradycardiaPacemaker-Induced CardiomyopathyConduction Block, AtrioventricularCardiac Remodeling, VentricularHeart FailureNCT05910866Azienda Ospedaliero Universitaria Maggiore della Carita130
尚未招募
不适用
Role of Left Bundle Branch (LBB) pacing in heart failure - An Observational StudyProlonged QRSduration (QRSd) >150 msLeft Bundle Branch Block (LBBB)Right Bundle Branch Block (RBBB)Cardiovascular - Other cardiovascular diseasesHeart FailureACTRN12623000088640DR. RAJEEV PATHAK150
招募中
不适用
Left Bundle Branch Pacing Versus Right Ventricular Pacing in Patients With Atrioventricular BlockAVB - Atrioventricular BlockNCT05722379West China Hospital1,000
招募中
不适用
Pacing of Left Bundle Branch Area and Atroventricular Node ablatIon in Patients With Symptomatic Atrial FibrillationAtrial Fibrillation (AF)NCT06699342Seoul National University Hospital50
已完成
不适用
Acute Effects of LBBP Versus BVP for CRTCardiac Pacing, ArtificialCardiac Resynchronization TherapyHeart FailureNCT04505384Shanghai Zhongshan Hospital25