跳至主要内容
临床试验/NCT00696371
NCT00696371已完成不适用

PET Imaging of Peripheral Benzodiazepine Receptors Using [11C](R)-PK 11195 and [11C]PBR28

National Institute of Mental Health (NIMH)1 个研究点 分布在 1 个国家目标入组 15 人开始时间: 2008年6月6日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
15
试验地点
1
主要终点
The first goal of this study is to compare [11C]PBR28 and [11C](R)-PK 11195 as radioligands in the measurement of PBR in healthy human subjects. Our primary outcome measures will be the distribution volume and time stability of each radioligand.

研究概览

简要总结

This study will use positron emission tomography (PET) to measure a receptor in the brain that is involved in inflammation. It will test two radioactive chemicals used in the procedure to see if the newer chemical, [(11)C]B, is as good or better than the older one, [(11)C]A, for measuring brain inflammation.

Healthy volunteers 18 years of age and older may be eligible for this study. Participants undergo an evaluation, [(11)C]A PET scan, [(11)C]B PET scan and magnetic resonance imaging (MRI), as follows:

Evaluation

Medical history and physical examination, blood and urine tests

PET scans

  • [(11)C]A scan. A catheter (plastic tube) is placed in an arm vein for injection of the [(11)C]A isotope. Some patients also have a catheter placed in an artery in the wrist to collect arterial blood samples during the scan. Subjects then lie on the scanner bed and a special mask is fitted to the head to help keep the subject s head still during the procedure. Following an 8-minute scan to calibrate the scanner, the [(11)C]A is injected into the catheter in the vein and pictures are taken that show where chemicals related to inflammation are present. The procedure takes about 2.5 hours.
  • [(11)C]B scan. The procedure is the same as above for [(11)C]A, except the isotope used is [(11)C]B.

MRI scan.

This test uses a strong magnetic field and radio waves to obtain images of body organs and tissues. The subject lies on a table that can slide in and out of the scanner (a metal cylinder), wearing earplugs to muffle loud noises that occur during the scan.

...

详细描述

Objective:

In response to brain inflammation, microglia over-express the peripheral benzodiazepine receptor (PBR). Although peripheral organs such as the heart and kidney express PBR constitutively, the brain normally expresses PBR in low numbers. Increased PBR density in the brain therefore signifies a change from a normal state to an active, inflammatory state. Positron emission tomography (PET) imaging can quantify PBR density in vivo using radioligands that bind to PBR sites. One PBR-selective radioligand, [(11)C](R)-PK 11195, has been used to identify areas of brain inflammation in patients with various neurological diseases. Unfortunately, [(11)C](R)-PK 11195 has several limitations, including low specific signal. A recently developed radioligand, [(11)C]PBR28, has higher specificity than [(11)C](R)-PK 11195 for PBR in animal studies. No study to date has compared [(11)C]PBR28 to [(11)C](R)-PK 11195 in human subjects.

In early clinical studies using [(11)C]PBR28, 4 of 32 healthy human subjects had complete absence of radioligand binding, even in peripheral organs that constitutively express PBR. One of these non-binders had specific binding of PBR28 on an in vitro assay using peripheral lymphocytes. We do not know why some subjects have [(11)C]PBR28 binding while others do not. We also do not know why one non-binder had positive in vitro binding and negative in vivo binding on PET imaging. No study has reported absent binding with [(11)C](R)-PK 11195. In order to better understand the phenomenon of non-binding, we need to obtain [(11)C](R)-PK 11195 PET scans in subjects that are [(11)C]PBR28 non-binders.

Study Population:

This protocol will study a total of 30 healthy human volunteers.

研究设计

研究类型
Observational
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • 未提供

排除标准

  • 未提供

结局指标

主要结局

The first goal of this study is to compare [11C]PBR28 and [11C](R)-PK 11195 as radioligands in the measurement of PBR in healthy human subjects. Our primary outcome measures will be the distribution volume and time stability of each radioligand.

次要结局

  • The second goal is to identify non-binders, that is, subjects that do not demonstrate any binding to [11C]PBR28.

研究者

申办方类型
Nih
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验