Comparison of microMend® Devices to Sutures in Closing Lacerations in Children
试验速览
- 阶段
- 不适用
- 入组人数
- 30
- 试验地点
- 2
- 主要终点
- Investigator's Assessment of Wound Closure Device (Questionnaire)
研究概览
简要总结
This study will gather information on the use of microMend® to repair lacerations in children and compare the efficacy of microMend® to sutures for laceration repair. microMend® has previously been shown to be less painful and easier to use than sutures, which are the current standard of care for primary wound closures. Results of this research will inform how the treatment of laceration repairs in the pediatric patient population.
详细描述
Lacerations are typically closed with sutures, staples, tissue adhesives, or bandages. These methods come with several limitations, however. Sutures and staples can be painful, cause inflammation that can lead to scarring, and require return clinic visits for their removal. Tissue adhesives cannot be used to close wounds under tension, can be associated with inflammation, and carry a risk of wound dehiscence. Bandages are also only useful for closing superficial wounds under low tension. Therefore, there is a need for improved products to close wounds associated with laceration repair.
The current study will use a prospective randomized controlled design to compare the use of sutures to microMend® to treat lacerations among children 7-17 years. Performance of sutures and microMend® will be assessed by investigators, providers and subjects. Participants will be randomized 1:1 between closure of lacerations with microMend® or sutures. Results from this study will help gather further information on the use of microMend® to close wounds in the pediatric population.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 7 Years 至 17 Years(Child)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Subjects undergoing a laceration repair that would require sutures, staples, or tissue adhesives to close the skin wound.
- •Age between 7 and 17 years old
- •Written informed consent obtained from Subject or Subject's legal representative
- •Ability of Subject to comply with the requirements of the study
排除标准
- •Wound in extensor or flexor surface of knee or elbow
- •Wound on concave areas of the face, such as orbit of the nasal sidewall
- •Wound on fingers or toes
- •Wound under high tension
- •Wound that has a gap of more than 1 cm between the wound edges immediately prior to application of microMend devices
- •Facial or body hair that could impede application of the wound closure device
- •Wound with significant tissue injury
- •Wound with active bleeding
- •Wound where adjacent skin is wet
- •Visual evidence of active infection, contaminated or devitalized tissue, or rash at laceration location
- •Wound that contain a foreign body
- •Wound site that contains tattoo or other identifiable features
- •Subject with keloid(s)
- •Medical disorder that, in the opinion of the Investigator, could have a significant effect on wound healing
- •Pregnancy
- •Inability of Subject to carry out Subject instructions
- •Subject lacks the capacity to consent
- •Currently using medication that, in the opinion of the Investigator, could have a significant effect on wound healing
- •Skin disorder, such as psoriasis, or current dermatitis or eczema at wound site
- •History of keloids or scar hypertrophy
- •Known bleeding diathesis
- •Sensitivity or allergy to adhesives or medical tape
- •Active infection in any part of the body
- •Use of sutures or staples to close underlying skin layers
- •Use of staples to close skin wound
- •Use of tissue adhesive or other adhesives directly over the wound
结局指标
主要结局
Investigator's Assessment of Wound Closure Device (Questionnaire)
时间窗: During wound-closure performance
The investigator will complete a questionnaire about the wound. The questionnaire will capture information about the wound including the cause of laceration, approximate length of the wound, and whether subcutaneous sutures were used prior to application of micro Mend or sutures. The questionnaire will also indicate whether local anesthesia was used.
Investigator's Assessment of Wound Closure Device (Survey)
时间窗: During wound-closure procedure
The investigator will rate the performance of the wound closure device using a survey to rate the ease of use, speed of use, wound appearance, and provide an overall rating for the experience of using the wound closure device. Each parameter will be determined to be Excellent, Good, Fair or Poor, which correspond to numerical ratings of 4, 3, 2, and 1, respectively.
次要结局
- Wound Closure Time(During wound-closure procedure)
- Total Procedure Time(During wound-closure procedure)
- Comparison of Provider's rating of wound closure results with microMend to suture(1 month after wound-closure procedure)
- Subject assessment of level of stress during removal of wound closure device(The VAS Score for level of stress during removal of the wound closure device will be collected on the day of the wound closure procedure (Study Day 0).)
- Subject assessment of level of stress during wound closure procedure(The VAS Score for level of stress during the wound closure procedure will be collected on the day of the wound closure procedure (Study Day 0).)
- Visual Assessment of wound in individual Subjects taken both before and after application of wound closure device(Photographs will be taken both before and after application of the wound closure device on the day of the wound closure procedure (Day 0). Photographs will be reviewed by an Independent Plastic Surgeon to assess wound appearance and cosmetic results.)
- Subject assessment of level of pain during wound closure procedure(The VAS Score for level of pain during the wound closure procedure will be collected on the day of the wound closure procedure (Study Day 0).)
- The VAS Score for level of stress during the wound closure procedure will be collected on the day of the wound closure procedure (Study Day 0).(The VAS Score for level of pain during removal of the wound closure device will be collected at the First Return Clinic Visit, Day 5 (5-7) for facial lacerations or Day 8 (7-10) for lacerations elsewhere on the body.)
- Visual Assessment of wound in individual Subjects taken both before and after removal of wound closure device(Photographs will be taken both before and after removal of the wound closure device on the day of the wound closure procedure (Day 5-7 for facial lacerations, Day 7-10 for lacerations elsewhere on the body). Photographs will be reviewed by an Independent)
- Visual Assessment of wound after 1 Month(A minimum of two photographs of each wound will be taken 1 month after initial application of the wound closure device. Photographs will be reviewed by an Independent Plastic Surgeon to assess wound appearance and cosmetic results.)
- Visual Assessment of wound after 3 Months(A minimum of two photographs of each wound will be taken 3 months after initial application of the wound closure device. Photographs will be reviewed by an Independent Plastic Surgeon to assess wound appearance and cosmetic results.)