Computer Designed and Chairside Fabricated Custom Tunnel Attachments Paired With Clear Aligners Versus Traditional Clear Aligners for Orthodontic Leveling and Aligning- A Randomized Controlled Clinical Trial
试验速览
- 阶段
- 不适用
- 入组人数
- 34
- 主要终点
- 3) angular movement in degrees
研究概览
简要总结
Incorporating wire threaded custom tunnel attachments with clear aligner therapy is a novel approach developed to address the shortcomings of the currently available orthodontic systems. This hybrid system is anticipated to take advantage of the benefits and overcome many of the limitations of traditional fixed buccal/lingual appliances and clear aligner therapy. The concept utilizes light arch wires to be threaded through computer designed, chairside-fabricated composite tunnel attachments to achieve better control of three-dimensional tooth movements not achievable by clear aligners, such as Invisalign® (Align Technology, Santa Clara, CA) alone. The superelastic feature of the arch wires allows delivery of more continuous forces than aligners alone, potentially permitting shorter duration of recommended aligner wear during orthodontic treatment. A virtual set-up would be used to plan the desired position of the teeth, which in turn will be used to customize the size and position of composite tunnel attachments based on how two round arch wires will pass through tubes within the attachments. The attachments can be placed on either the buccal or lingual surfaces of teeth, depending on clinical preferences and esthetic demands. This is achievable using in-house aligners, which will also allow the fabrication of aligners in the office or at a conventional orthodontic lab at a fraction of the cost of traditional clear aligners.
详细描述
Specific aims:
-
Test and formally describe a novel method that utilizes clear aligners paired with computer-designed, chairside-fabricated tunnel attachments to achieve tooth movements that are challenging for clear aligners.
-
Conduct a randomized clinical trial to compare the ability of a traditional clear aligner system Invisalign® (Align Technology, Santa Clara, CA) and a clear aligner system incorporating wire threaded tunnel attachments in:
-
achieving predicted outcomes; discrepancies in bucco-lingual and inciso-gingival positions between the virtual plan and end of treatment intraoral scan and will be measured in millimeters and angular discrepancies will be measured in degrees
-
end of treatment ABO leveling and alignment objective grading scores
Materials and Methods
A virtual set-up is completed by the clinician to plan the position, orientation, and dimension will be customized on the teeth to be moved.Generally, they are spherically shaped and their dimensions are approximately 2-3 mm. Vacuum-formed attachment template will be made to take the shape of a tube-holding spheres, in which tubes are embedded. The tubes are standard in size with an outside diameter of 0.032", and an inside diameter of 0.019" and 2 mm length The template will be loaded with composite after inserting the metal tubes are placed in their predetermined location on the tray. Double tubes will be used when torque control is needed. 0.016" buccal or lingual round wires will be placed into the tunnel attachments along the attachments. Aligners will be delivered to patient to be worn for at least 8 hours a day and changed as determined by the Dental Monitoring application.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- Triple (Care Provider, Investigator, Outcomes Assessor)
入排标准
- 年龄范围
- 12 Years 至 65 Years(Child, Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •healthy subjects over the age of 10 years and below 65;
- •eruption of all permanent anterior teeth;
- •non-extraction treatment;
- •maximum of 7mm of crowding/spacing;
- •no more than 45 degrees of rotations
- •no more than 7 mm crowding
排除标准
- •presence of systemic diseases, cleft lip and palate, craniofacial anomalies, syndromes affecting bone or teeth, impacted teeth (excluding 3rd molars), congenitally missing lateral incisors, and tumors of the parathyroid gland;
- •the presence of bridges or implants replacing anterior teeth;
- •cases requiring orthognathic surgery;
- •significant (> moderate) periodontal disease, intake of drugs affecting tooth movement or bone formation (chronic use of Non-Steroidal Anti-Inflammatory Drugs, bisphosphonates, levothyroxine, or teriparatide drug class), pregnancy;
- •cases requiring tooth extractions
研究组 & 干预措施
Clear aligners with tunnel attachment
Participants will receive traditional clear aligner therapy with virtual set up and will be supplemented by virtually planned tunnel attachments which will be threaded by a light Nickel-Titanium wire
干预措施: Tunnel attachments and light Nickel Titanium wire (Device)
Clear aligners
Participants will receive traditional clear aligner therapy with virtual set up
干预措施: Clear Aligner therapy (Device)
结局指标
主要结局
3) angular movement in degrees
时间窗: 3-12 months of orthodontic treatment
The virtual setups (predicted results) and actual results scans will be superimposed using a best-fit alignment method using Geomagic Control X (3D Systems, Rock Hill, South Carolina). Initial alignment will be done using 300 surface points, and fine adjustments will be made using additional 1500 points. This process will be repeated as necessary. Once satisfactory superimposition is performed, the x, y, z coordinates (mm) of dental landmarks on the setup and result arches will be exported and analyzed. Linear and angular measurements will be made to determine the accuracy of each system in achieving predicted vertical, in-out and torque treatment outcomes. The percentage of accurate tooth movement will be determined with the following equation: \[(\|predicted-achieved\|/\|predicted\|) 100%\]
1) Horizontal movement in millimeters
时间窗: 3-12 months of orthodontic treatment
The virtual setups (predicted results) and actual results scans will be superimposed using a best-fit alignment method using Geomagic Control X (3D Systems, Rock Hill, South Carolina). Initial alignment will be done using 300 surface points, and fine adjustments will be made using additional 1500 points. This process will be repeated as necessary. Once satisfactory superimposition is performed, the x, y, z coordinates (mm) of dental landmarks on the setup and result arches will be exported and analyzed. Linear and angular measurements will be made to determine the accuracy of each system in achieving predicted vertical, in-out and torque treatment outcomes. The percentage of accurate tooth movement will be determined with the following equation: \[(\|predicted-achieved\|/\|predicted\|) 100%\]
2) Vertical movement in mm
时间窗: 3-12 months of orthodontic treatment
The virtual setups (predicted results) and actual results scans will be superimposed using a best-fit alignment method using Geomagic Control X (3D Systems, Rock Hill, South Carolina). Initial alignment will be done using 300 surface points, and fine adjustments will be made using additional 1500 points. This process will be repeated as necessary. Once satisfactory superimposition is performed, the x, y, z coordinates (mm) of dental landmarks on the setup and result arches will be exported and analyzed. Linear and angular measurements will be made to determine the accuracy of each system in achieving predicted vertical, in-out and torque treatment outcomes. The percentage of accurate tooth movement will be determined with the following equation: \[(\|predicted-achieved\|/\|predicted\|) 100%\]
次要结局
未报告次要终点
研究者
Alyaa Aldohan
Orthodontic resident and Doctor of Medical Sciences candidate
Harvard School of Dental Medicine