临床试验/NCT01943916
NCT01943916已完成不适用

A Study of Imaging With Opto-acoustics to Diagnose Breast Masses Detected by Mammography and/or Diagnostic Ultrasound: A New Evaluation Tool for Radiologists

Seno Medical Instruments Inc.32 个研究点 分布在 1 个国家目标入组 2,105 人开始时间: 2012年12月21日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
2,105
试验地点
32
主要终点
Specificity Difference Between Imagio Optoacoustic Plus Gray-scale (OA/US) vs Imagio Gray-scale Ultrasound (IUS)

研究概览

简要总结

This is a prospective controlled multi-center study involving gray scale (B-mode) ultrasound vs OA/US (opto-acoustic and gray scale ultrasound) for the visualization of suspicious masses. Imagio gray scale and OA image sets will be collected on each enrolled mass and pushed to an Imaging Core Lab for processing and then to a set of Independent Readers who will read the Imagio gray-scale images vs the Imagio OA/US images.

详细描述

Imagio is a multi-modality device, comprised of one probe with the ability to image with diagnostic gray scale (B mode) ultrasound alone and gray scale in conjunction with OA together in a six up image.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Sequential
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
Female
接受健康志愿者

入选标准

  • 18 years of age or older
  • suspicious mass of breast, identified by a health care practitioner within the past 30 days with diagnostic methodology other than conventional ultrasound.

排除标准

  • presence of a condition or impediment that may interfere with imaging.
  • pregnant or lactating
  • undergoing neoadjuvant therapy

结局指标

主要结局

Specificity Difference Between Imagio Optoacoustic Plus Gray-scale (OA/US) vs Imagio Gray-scale Ultrasound (IUS)

时间窗: Baseline to 12 months +/- 30 days follow-up

Primary effectiveness endpoint was the difference in specificity for the Imagio OA/US relative to IUS, across all 7 independent readers; both imaging modalities used in each subject (subject as own control); results for each imaging modality compared to biopsy diagnosis or 12-month follow-up ruling of benign as determined by truth panel (ground truth)

次要结局

  • Sensitivity Difference Between Imagio Optoacoustic Plus Gray-scale (OA/US) vs Imagio Gray-scale Ultrasound (IUS)(Baseline to 12 months +/- 30 days follow-up)
  • Specificity for Each Imaging Modality Imagio Optoacoustic Plus Gray-scale OA/US and Imagio Gray-scale Ultrasound (IUS)(Baseline to 12 months +/- 30 days follow-up)
  • Sensitivity for Each Imaging Modality Imagio Optoacoustic Plus Gray-scale (OA/US) and Imagio Gray-scale Ultrasound (IUS)(Baseline to 12 months +/- 30 days follow-up)
  • Downgrade Benign Masses Imagio Optoacoustic Plus Gray-scale (OA/US) vs Imagio Gray-scale Imaging (IUS)(Baseline to 12 months +/- 30 days follow-up)
  • Upgrade Cancer Masses - Imagio Optoacoustic Plus Gray-scale (OA/US) vs Imagio Gray-scale Imaging (IUS)(Baseline to 12 months +/- 30 days follow-up)