Intraoperative Investigation of a Directional Lead and Local Field Potentials for the Optimization of Stimulation Efficacy

Abbott Medical Devices1 个研究点 分布在 1 个国家目标入组 10 人开始时间: 2018年7月12日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
10
试验地点
1
主要终点
Number of DBS Leads With Clinical Programming at 3 Months That Were Consistent With Predictions Via LFP Features After DBS Implant Procedure

研究概览

简要总结

The current study aims to explore the functional use of LFPs recorded intraoperatively for the optimization of a directional DBS lead programming

Aim-1: To determine whether intraoperative LFPs recorded from the segmented DBS electrode can predict the optimal stimulation parameters.

Aim-2: Compare the therapeutic window for stimulation delivered through directional and conventional leads and determine if the spatiospectral LFP patterns correlate with the presence of stimulation side effects.

详细描述

This is a feasibility study designed to evaluate the usefulness of intraoperative LFP recordings obtained from the implanted DBS lead to predict ideal stimulation parameters. Additionally this study will compare the therapeutic window for stimulation delivered through directional and conventional leads and determine if the spatiospectral LFP patterns correlate with the presence of stimulation side effects.

Approximately 15 subjects will be enrolled in this clinical investigation. The clinical investigation will be conducted at 2 centers in the USA.

Subjects participating in this clinical investigation will monitored during DBS implant procedure and programming. The expected duration of enrollment is 8 months. The total duration of the clinical investigation is expected to be 1 year.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Prospective

入排标准

年龄范围
18 Years 至 70 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Age 18-70 years
  • Ability to provide informed consent
  • Diagnosis of idiopathic Parkinson's disease, and DBS consensus team review supporting the placement of STN DBS.

排除标准

  • Subject is not a surgical candidate;
  • In the Investigator's opinion the subject unable to tolerate multiple programming sessions within a single setting;
  • Subject unable to comply with the follow-up schedule

结局指标

主要结局

Number of DBS Leads With Clinical Programming at 3 Months That Were Consistent With Predictions Via LFP Features After DBS Implant Procedure

时间窗: LFPs were analyzed after DBS implant procedure, clinical programming were done at 3 month followup

From all DBS leads (2 per patient): Local field potentials (LFPs) were measured intraoperatively during DBS implant. Features such as beta band power (10-30Hz), high-frequency oscillation power (200-400Hz, HFO), as well as the cross frequency coupling between beta band power and HFO (CFC) were extracted from the LFP recordings from all electrodes. Electrodes with the most beta band power, most HFOs, and most CFC were documented. At 3 month post-op visit, the clinically programmed stimulation electrodes were documented, and were compared to the electrodes documented from the intraoperative LFP measures. Both matches in the exact contact and the row at which the contacts were in were documented and compared.

次要结局

  • Number of DBS Leads With the Highest Side Effect Threshold at 3 Months That Were Consistent With Predictions Derived From LFPs After DBS Implant Procedure(LFPs were measured during DBS implant procedure, clinical programming were done at 3 month followup evaluation)

研究者

申办方类型
Industry
责任方
Sponsor