CTRI/2019/05/019126尚未招募不适用
Comparison of the clinical performance of I-gel and Ambu Aura Gain -supra-glottic airway devices in paediatric patients under controlled ventilation.
Ashka V Surve1 个研究点 分布在 1 个国家目标入组 60 人开始时间: 2019年5月23日最近更新:
试验速览
- 阶段
- 不适用
- 状态
- 尚未招募
- 发起方
- 入组人数
- 60
- 试验地点
- 1
- 主要终点
- The oropharyngeal seal pressure of I-gel is higher than Ambu Aura Gain in their individual studies. Whereas insertion of Ambu aura gain is faster than I-Gel.
研究概览
简要总结
| As newer pediatric sized supra-glottic airway devices like I-gel and Ambu Aura Gain are available for use in clinical practice in children. It is important to evaluate their clinical performance and safety to establish superiority or equivalence to the existing devices. So, we choose this study to evaluate and compare overall performance of I-gel versus Ambu Aura Gain in pediatric patients undergoing general anesthesia. To compare the clinical performance of I gel with Ambu Aura Gain in pediatric population for providing adequate airway seal under controlled mechanical ventilation under general anesthesia. |
研究设计
- 研究类型
- Interventional
- 分配方式
- Computer generated randomization
- 盲法
- Participant Blinded
入排标准
- 年龄范围
- 3.00 Year(s) 至 10.00 Year(s)(—)
- 性别
- All
入选标准
- •1.Patients age group 3-10 years 2.Either gender 3.Weight 10-35 kg 4.ASA physical status I/II 5.Patients admitted in SSGH and posted for 6.Elective surgeries requiring general anesthesia ( abdominal surgeries, upper limb surgeries, lower limb surgeries, head and neck surgeries etc.
排除标准
- •1.Patient with risk factors of difficult airway (mouth opening of < 2cm, mallampatti class III and IV, limited neck extension, history of previous difficult tracheal intubation).
- •2.Patients with recent upper respiratory tract infection.
- •3.Patient with any known pulmonary and cardiovascular diseases.
- •4.Patient with any conditions that increase the risk of gastro esophageal regurgitation.
- •5.Parents or guardian not willing for participation.
结局指标
主要结局
The oropharyngeal seal pressure of I-gel is higher than Ambu Aura Gain in their individual studies. Whereas insertion of Ambu aura gain is faster than I-Gel.
时间窗: at 5 minute after insertion of the device, oropharyngeal leak pressure will be noted.
次要结局
- Secondary outcomes are haemodynamic and respiratory parameters.(These secondary outcomes are observed throughout the duration of surgery.)
研究者
研究点 (1)
Loading locations...
相似试验
Unknown
不适用
The Effect Of I-Gel And Ambu Aura-I Use On Laryngofaryngeal MucosaMucosal DamageNCT04062747Bezmialem Vakif University40
已完成
不适用
A Comparison of the I-gel and the Self-pressurised Air-Q Intubating Laryngeal Airway in ChildrenGeneral AnesthesiaSupraglottic Airway DevicesNCT02140008Yonsei University80
已完成
不适用
Comparison of the LMA Protector and the I-gelMechanical VentilationNCT03078517SMG-SNU Boramae Medical Center110
尚未招募
不适用
Comparison between The two techniques of I-GEL insertionCTRI/2025/06/089121Shree Krishna hospital78
已完成
不适用
Evaluation of the i-gel supraglottic airway.1. i-gel<br /> 2. supraglottic airway<br />3. laryngeal mask (larynx masker)<br />4. sore throat (keelpijn).NL-OMON25310The Netherlands Cancer Institute - Antoni van Leeuwenhoek HospitalPlesmanlaan 1211066 CX Amsterdam240