An Open Label, Non-comparative, Pharmacokinetic and Pharmacodynamic Study to Evaluate the Effect of Dabigatran Etexilate on Coagulation Parameters Including a Calibrated Thrombin Time Test in Patients With Moderate Renal Impairment (Creatinine Clearance 30-50 ml/Min) Undergoing Primary Unilateral Elective Total Knee or Hip Replacement Surgery
试验速览
- 阶段
- 4 期
- 状态
- 已完成
- 入组人数
- 142
- 试验地点
- 10
- 主要终点
- Dabigatran Concentration in Plasma, Measured With HPLC-MS/MS
研究概览
简要总结
To supplement the current evidence of the effect of Pradaxa® (dabigatran etexilate) on coagulation parameters, including a calibrated thrombin time test, in patients with moderate renal impairment undergoing elective total hip- or knee-replacement surgery, this PK/PD study will be conducted.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Prevention
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- 未提供
排除标准
- 未提供
研究组 & 干预措施
Dabigatran etexilate
open label, once daily dose approved by EMEA and Health Canada
干预措施: Dabigatran etexilate (Drug)
结局指标
主要结局
Dabigatran Concentration in Plasma, Measured With HPLC-MS/MS
时间窗: At day 6 before drug intake (di), at 1h, 2h, 4h, 8h and 24h after di
Dabigatran Concentration in Plasma, measured with HPLC-MS/MS - Most relevant timepoints are reported here, ie timepoints of day 6
Dabigatran Concentration in Plasma, Estimated From Local Hemoclot®
时间窗: Screening, day of surgery 1 hour (h) and 2h after drug intake (di) for late finalization of surgery, 4h and 8h after di for early finalization of surgery, 15 minutes (min) before di at days 2, 3, 4, 5 and 6, at day 6 also 1h, 2h, 4h, 8h and 24 after di
The Hemoclot® test kit measures the dTT (diluted Thrombin time). In the present trial, as a first step, the dTT in calibration samples that had known Dabigatran concentrations was measured locally with the Hemoclot® test kit, and a linear calibration curve was fitted to the data from the calibration samples. Thereafter, for each patient at each time-point, the dTT was measured with the Hemoclot® kit and the Dabigatran concentration was read off from the calibration curve. These estimated concentrations are compared with concentrations measured in parallel with HPLC-MS/MS. As the trial objective is the method comparison and not the detection of the absolute concentrations of either of the methods, the result is reported as a relative bioavailability \[%\], see "Statistical Analysis 1" below. Only concentrations \>= LLOQ (Lower Limit of concentration) are included in the quantitative comparison.
Dabigatran Concentration in Plasma, Estimated From Central Hemoclot®
时间窗: Screening, day of surgery 1 hour (h) and 2h after drug intake (di) for late finalization of surgery, 4h and 8h after di for early finalization of surgery, 15 minutes (min) before di at days 2, 3, 4, 5 and 6, at day 6 also 1h, 2h, 4h, 8h and 24 after di
The Hemoclot® test kit measures the dTT (diluted Thrombin time). In the present trial, as a first step, the dTT in calibration samples that had known Dabigatran concentrations was measured centrally with the Hemoclot® test kit, and a linear calibration curve was fitted to the data from the calibration samples. Thereafter, for each patient at each time-point, the dTT was measured with the Hemoclot® kit and the Dabigatran concentration was read off from the calibration curve. These estimated concentrations are compared with concentrations measured in parallel with HPLC-MS/MS. As the trial objective is the method comparison and not the detection of the absolute concentrations of either of the methods, the result is reported as a relative bioavailability \[%\], see "Statistical Analysis 1" below. Only concentrations \>= LLOQ (Lower Limit of concentration) are included in the quantitative comparison.
次要结局
未报告次要终点