跳至主要内容
临床试验/NCT04388917
NCT04388917已完成不适用

Does the Use of Hemostatic Clips During the Tumor Resection Step Reduce Blood Loss During Robot-assisted Partial Nephrectomy?

Centre Hospitalier Universitaire de Nice0 个研究点目标入组 53 人开始时间: 2017年1月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
53
主要终点
Blood loss in the two groups was compared

研究概览

简要总结

One challenge of robot-assisted partial nephrectomy (RAPN) is to reduce operative blood loss. Partial nephrectomy (PN) is a complex surgery that is being made easier by robotic assistance. In this study, we determined whether the use of hemostatic clips during the tumor resection step reduced blood loss during robot-assisted partial nephrectomy. Methods: In this retrospective study, we included all consecutive patients who underwent RAPN in our university hospital from 2017 to 2019. Three experienced surgeons performed the surgery. One surgeon used Hemo-lock hemostatic clips during tumor resection to prevent bleeding, and two did not. Blood loss in the two groups was compared as the primary endpoint. The duration of clamping, operative time, complications, surgical margins, transfusions, serum creatinine and hemoglobin were compared as secondary endpoints. Results: 53 patients were included, 36 in the No-clip group and 17 in the Clip group. Our two groups were comparable for age, weight, Charlson score, tumor size and RENAL score. There was a significant difference between the two groups for median blood loss 50 mL in the Clip group versus 300 mL in the No-clip group (p = 0.0001), whereas median operating time was shorter in the No-clip group, 140 min versus 180 min for the Clip group (p = 0.044). No other criterion showed a significant difference. The use of Hemo-lock during the tumor resection step in RAPN reduced blood loss without impairing renal function. Larger studies are still needed to confirm our findings.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Retrospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • all consecutive patients who underwent Robot Assisted Partial Nephrectomy

排除标准

  • patient off clamping or partial clamping

结局指标

主要结局

Blood loss in the two groups was compared

时间窗: 3 years

It was mesured during the surgery by amount of blood drawn

次要结局

  • operative time(3 years)
  • duration of clamping(3 years)
  • incidence of complications(3 years)

研究者

申办方类型
Other
责任方
Sponsor