跳至主要内容
临床试验/NCT04515511
NCT04515511Unknown不适用

Medical Intensive Care Unit of PUMCH

Peking Union Medical College Hospital1 个研究点 分布在 1 个国家目标入组 50 人开始时间: 2019年7月1日最近更新:
适应症

试验速览

阶段
不适用
入组人数
50
试验地点
1
主要终点
Cardiac output

研究概览

简要总结

Assessment of fluid responsiveness (FR) is to detect whether patient could benefit from fluid therapy. Mini fluid challenge has been widely used in clinical practice to prevent patients from volume overload. In clinical practice, 100 mL or 250 mL have been used most frequently and FR was defined as an increase in CO greater than 10% as much as the changes in CO after infusion of 500 mL. While using a half of volume infusion and assessed by the traditional standard of FR, this might misclassify more patients as nonresponders. In that it is imperative to test the predictive ability of mini fluid and find out the threshold of cutoff value. Meanwhile, in almost mini-FC, cardiac output were measured by echocardiography(VTi) and pulse contour,None of the studies conducted cardiac output (CO)measurement by gold standard method of thermodilution by pulmonary artery catheter (PAC). The correlation between new generated CO measurements and PAC varies in different studies as well. It is imperative to investigate the reliability of mini-FC to predicting fluid responsiveness(FR).The investigator's study is to detect the predictive minimal volume using thermodilution by PAC in septic shock patient.

详细描述

Fluid therapy is the cornerstone of septic resuscitation. In recent decade, a restrictive fluid strategy has been applied to shock resuscitation for fewer complications and shorter hospital stays compared with a liberal fluid strategy. Therefore, it is a reasonable step to assess the patient's response to fluid infusion to avoid excessive fluid administration.Mini-fluid challenge allows the selection of fluid responders by inducible changes of hemodynamic parameters after changing the preload gaining popularity. The mini fluid challenge was firstly described by Muller et al. in 2011. They found an infusion of 100 mL colloid over 1 minute and the assessment by cardiac output using velocity time integral (VTi) at the aortic outflow tract could predict fluid responsiveness (FR). Since then, a total of seven investigations have been published. Although a mini-fluid challenge may help the decision-making process of fluid management, the investigation results differed from each other, especially in minimal volume and cut off value of hemodynamic parameters change. Meanwhile, we noticed that when measuring CO, the method of thermodilution by pulmonary artery catheter (PAC), which is the gold standard of CO measurement, was not used in these studies. Furthermore, the majority participants of the studies were perioperative patients in a stable hemodynamic state.Therefore, there are two question needed to be answered:what is the minimal infusion volume in effectively predicting fluid responsiveness, and whether mini-volume can perform a real change in septic shock patients. Thus, it is necessary to explore the minimal volume in fluid challenge by PAC and test its reliability in detecting responders (R) and nonresponders (NR).

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients diagnosis of septic shock and is required fluid challenge in the presence of invasive hemodynamic monitoring.
  • Patients with hypotension (SBP <90 mmHg or MAP <65 mmHg)
  • Patients with evidences of tissue hypoperfusion (including but not limited to oliguria, skin mottling, altered mental status, cool peripheries, hyperlactatemia, et al).

排除标准

  • Age less than 18yrs or greater than 80yrs
  • Shock is diagnosed with other types of shock
  • Known allergy to colloid fluids
  • Pregnancy
  • Recent participation in another biomedical study.

结局指标

主要结局

Cardiac output

时间窗: Baseline and immediately after each bolus of 100 mL colloid, average 3 minutes

Cardiac output measured by therm-dilution of pulmonary artery catheter. An increase in cardiac output(CO) greater than 10% after a volume expansion of 500 mL is defined as fluid responsiveness(FR).

次要结局

  • Mean arterial pressure(Baseline and immediately after each bolus of 100 mL colloid, average 1 minutes)
  • Hemoglobin(Baseline and immediately after each bolus of 100 mL colloid, average 3 minutes)
  • Central venous pressure(Baseline and immediately after each bolus of 100 mL colloid, average 1 minutes)
  • Oxygen saturation(Baseline and immediately after each bolus of 100 mL colloid, average 3 minutes)
  • Carbon dioxide partial pressure(Baseline and immediately after each bolus of 100 mL colloid, average 3 minutes)
  • Heart rate(Baseline and immediately after each bolus of 100 mL colloid, average 1 minutes)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验