Diagnostic yield Evaluation Studies of a real-time endoscopic Image diagNosis support system using Artificial Intelligence technology - DESIGN AI-02 Pilot Study

ational Cancer Center Hospital0 个研究点目标入组 110 人开始时间: 2020年9月25日最近更新:
适应症

试验速览

阶段
未知
状态
已完成
入组人数
110

研究概览

简要总结

The overall adenoma detection rate was 49.1% (95% CI: 39.4% to 58.8%), the polyp detection rate was 60.9% (51.1% to 70.1%), the average polyps per colonoscopy was 1.7 (1.33 to 2.10), the false detection rate was 36.4% (27.4% to 46.1%), the detection rate of diminutive polyps was 0% (0% to 3.3%), and the right-sided colon detection rate was 4.5% (1.5% to 10.3%). The median insertion time was 5.6 (ranging from 1.5 to 25) minutes, and the median observation time was 10.4 (ranging from 3.8 to 29.9) minutes.

研究设计

研究类型
Observational

入排标准

年龄范围
20years-old 至 90years-old(—)
性别
All

入选标准

  • 未提供

排除标准

  • 1) Familial adenomatous polyposis 2) Patients with complications, such as chronical hematological disease 3) Patients with active inflammatory bowel diseases, such as ulcerative colitis or Crohn's disease