The Effects of Endotracheal Tube Fixation Methods on Hemodynamic Parameters During Endotracheal Suction in Cardiovascular Surgery Intensive Care Patients
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 86
- 主要终点
- Blood pressure
研究概览
简要总结
Background: Endotracheal suction (ES), may cause changes like increase in blood pressure, heart rate (HR) and decrease in peripheral oxygen saturation (SpO2), which may cause changes in hemodynamic parameters (HPs) that increase the workload of the heart after surgery.
Aim: The aim of this study is to determine the effect of the methods used in endotracheal tube (ET) fixation on HPs [systolic blood pressure (SBP), diastolic blood pressure (DBP), HR and SpO2] during ES.
Study Design: The sample of this prospective, single-blind non-randomized clinical trial study included 86 intubated patients who were treated in the cardiovascular surgery intensive care unit (CVSICU) of a university hospital between September 2016 and December 2017.
Methods: The ET fixations of the experimental group (n=43) were performed with tube holders while the ET fixations of the control group (n=43) were performed using plasters. The HPs of the patients were measured before, during, at the end of suction and 5 and 15 minutes after suction.
详细描述
Information collected from the relatives of the patient, patient file and the health care workers was used to fill out the "Patient Information Form".
When the study started, the first 43 patients were assigned to the control group and the following 43 patients were assigned to the study group in the CVS ICU. ET fixation in the control group was performed with plasters, which are routinely used in the ICU where the study was conducted. ET fixation of the patients in the study group was performed with an ET holder (AnchorFast Oral Endotracheal Tube Fastener, Hollister, Liberlyville, USA) when they arrived at the CVS ICU.
When the findings of patients' suction needs were observed (increase in respiratory rate, HR increase, arterial BP increase, high pressure alarm in ventilator, mucus in ET, cyanosis, dyspnea, restlessness, sweating, disturbance of blood gas parameters, wheezing, etc.), endotracheal suction was performed according to the application standards. The patients' SBP, DBP, HR and SpO2 values, which were displayed on the bedside monitor (Nihon Kohden, Tokyo), were recorded on the "Hemodynamic Parameters Form" just before, during, and at the end of endotracheal suction, and in the following 5th and 15th minutes.
During the suction process, it was ensured that the patients were in the supine position in which the head of the bed was lifted by 30 degree Before the intra-arterial BP was measured, the transducer was reset at the level of the right atrial (plebostatic axis) and the position was not changed during all the measurements.
研究设计
- 研究类型
- Interventional
- 分配方式
- Non Randomized
- 干预模型
- Parallel
- 主要目的
- Supportive Care
- 盲法
- Single (Participant)
盲法说明
In this study only the patient was blinded. Investigators involved with the running of the study were not blinded.
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •postcardiac surgery
- •having endotracheal tube
排除标准
- •pulmonary problems
结局指标
主要结局
Blood pressure
时间窗: During the suction process
systolic blood pressure (SBP), diastolic blood pressure (DBP), mmHg
Heart rate
时间窗: During the suction process
beats per minute
peripheral oxygen saturation
时间窗: During the suction process
%, percentage of oxygenated hemoglobin in peripheral arterial blood
次要结局
未报告次要终点
研究者
Gulay ALTUN UGRAS
Associate Professor
Mersin University
